® RIM100 Run Indicator Module User’s Manual Revision 1.1 Copyright © 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com Maretron Manual Part #: M002001 Revision 1.
RIM100 User's Manual Revision History Revision Description 1.0 Original document 1.1 Added prohibition of red Loctite threadlocking compound and cleaning agents containing acetone Page ii Revision 1.
® Table of Contents 1 Introduction ...........................................................................................................................1 1.1 Firmware Revision .................................................................................................... 1 1.2 RIM100 Features ...................................................................................................... 1 1.3 Quick Install ...................................................................................
RIM100 User's Manual This page intentionally left blank Page iv Revision 1.
® 1 Introduction Congratulations on your purchase of the Maretron Run Indicator Module (RIM100). Maretron has designed and built your RIM100 to the highest standards for years of dependable and accurate service. Maretron’s RIM100 monitors both AC and DC electrical circuits and reports, over an NMEA 2000® network, whether or not the electrical circuit is energized and running. The RIM100 works equally as well for monitoring manually switched loads (e.g.
RIM100 User's Manual 3. Mount the RIM100 (Section 2.3) 4. Connect the RIM100 (Section 2.4) 5. Configure the RIM100 (Section 2.5) 2 Installation 2.1 Unpacking the Box When unpacking the box containing the Maretron RIM100, you should find the following items: 1 – RIM100 – Run Indicator Module 1 – Parts Bag containing 4 Stainless Steel Mounting Screws 1 – RIM100 User’s Manual 1 – Warranty Registration Card If any of these items are missing or damaged, please contact Maretron. 2.
® 2.3 Mounting the RIM100 Attach the RIM100 securely to the vessel using the included stainless steel mounting screws or other fasteners as shown in Figure 1 below. Do not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as they will cause stress cracking of the plastic enclosure. Figure 1 – Mounting the RIM100 2.4 Connecting the RIM100 The RIM100 requires two types of electrical connections: 1) the NMEA 2000® connection (refer to Section 2.4.
RIM100 User's Manual Figure 2 – NMEA 2000® Connector Face Views 2.4.2 Monitored Load Connections The RIM100 monitored load connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the corners of the unit detaching the splash guard from the unit. On the bottom of the splash guard, you will find a label detailing the wire connection to pin number assignments, which are repeated in the table below.
® WARNING: The voltages present on AC circuits can cause electrocution. Before making any electrical connections to the RIM100, ensure that power is removed from all AC circuits that will be connected to the RIM100. Only restore AC power after all connections have been made to the RIM100 and the splash guard has been re-installed.
RIM100 User's Manual User-Supplied Components Power Switch Fuse Monitored AC Load To AC Breaker Panel Fuse RIM100 Screw Terminals 2 3 4 5 6 7 8 9 10 11 12 V1+ V1V2+ V2V3+ V3V4+ V4V5+ V5V6+ V6- 1 Figure 4 – AC Single-Phase (Ph. A,B) or AC Three-Phase Load Connection Diagram 2.4.2.2 DC Load Please refer to Figure 5 for connecting the RIM100 to a DC load.
® 2.4.3 Checking Connections Once the NMEA 2000® connection and load connection(s) to the RIM100 have been completed, check to see that information is being properly transmitted by observing an appropriate NMEA 2000® display. If you don’t see Run Indicator status, refer to Section 4, “Troubleshooting”. 2.
RIM100 User's Manual 2.5.5 NMEA 2000® PGN Enable/Disable The RIM100 is capable of transmitting NMEA 2000® messages (or PGNs) associated with monitored load circuits. You may individually enable or disable each of these messages. You may also change the rate of transmission of each of these messages if desired. 2.5.6 Restore Factory Defaults Selecting this configuration option causes all stored parameters in the RIM100 to be reset to the values they contained when the unit was manufactured. 2.5.
® Symptom No Run Indicator data visible on NMEA 2000® network. Troubleshooting Procedure Ensure that the RIM100 is properly connected to the NMEA 2000® network. Ensure that the monitored loads are properly connected to the RIM100. Ensure that each indicator that you wish to monitor is not configured as “Disabled”. A Run Indicator always reads “Off” Revision 1.1 Ensure that the RIM100 has the appropriate NMEA 2000® PGNs enabled as described in Section 2.5.5.
RIM100 User's Manual 5 Technical Specifications As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretron products are designed to be accurate and reliable; however, they should be used only as aids to navigation and not as a replacement for traditional navigation aids and techniques.
® Environmental Parameter IEC 60945 Classification Degree of Protection Operating Temperature Storage Temperature Relative Humidity Vibration Solar Radiation Corrosion (Salt Mist) Electromagnetic Emission Electromagnetic Immunity Safety Precautions Value Exposed IP64 -25°C to 55°C -40°C to 70°C 93%RH @40° per IEC60945-8.2 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.
RIM100 User's Manual 7 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions. Figure 6 – Mounting Surface Template Page 12 Revision 1.
® 8 Maretron (2 Year) Limited Warranty Maretron warrants the RIM100 to be free from defects in materials and workmanship for two (2) years from the date of original purchase. If within the applicable period any such products shall be proved to Maretron’s satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Maretron’s option.
RIM100 User's Manual This page intentionally left blank Page 14 Revision 1.
® Appendix A – NMEA 2000® Interfacing RIM100 NMEA 2000® Periodic Data Transmitted PGNs PGN 127501 – Binary Switch Bank Status The RIM100 uses this PGN to transmit the state of each of the connected switch inputs Field 1: Indicator Bank Instance – This field identifies the particular switch bank to which this PGN applies. Please refer to Section 2.5.1 for instructions on how to program the value of this field.