Figure 106 – Custom Tank Level Calibration Confirmation Screen
6.13.2.1.6.2 Rectangular Tank
This menu allows calibration of the FPM100 for tanks with a rectangular cross-section.
Empty Tank Depth - enter the depth of the fluid when the tank is empty (this distance is usually zero)
Full Tank Depth - enter the depth of the fluid when the tank is full (this is the distance from the
surface of the fluid to the bottom of the tank)
Fluid Density - enter the density of the fluid whose depth is being measured. There are preset values
for various types of diesel fuels, as well as gasoline and water.
Figure 107 – Rectangular Tank Calibration
6.13.2.1.7 Tank Number
The Tank Number is the Data Instance used in the data message. This can be set from #0 to #15.
6.13.2.1.8 Tank Type
This is set to the type of fluid in the tank. Values are: