c) When utilizing expansion screws for sheetrock mounting, hold the unit on the wall
where you want it mounted. Mark with a pencil the (4) mounting holes. Remove the
unit from the wall, and drill 3/8" holes on each mark. (See drawings below).
d) Install the expansion bolt into the drilled hole. Hang the unit utilizing the screws
supplied.
WATER SUPPLY
Connect the cold water inlet supply
Note: Use white Teon tape at all threaded water connections
- The cold water inletjoint is ½" NPT threaded pipe.
- The water inlet should be connected by using exible heavy duty tubing or rigid PVC
pipe. If you choose exible tubing, you will need a½" threaded male to½" hose barb
adapter. Tubing should be secured with properly sized hose clamps. Rigid pipe should
be ½" male threads. Teon tape should be employed with any threaded ttings.
- The inner diameter of the inlet pipe (including the valve) should not be less than 3/8".
Larger diameter pipe is acceptable with the appropriate adapters to reduce to ½" at the
inletjoint.
-The cold water valve must be installed inline with the water inlet pipe.
- Always ush a new unit with water to clear out any collected deposits or debrisprior
to installation. The supplied screen lter must be correctly installed in the cold water
inlet to prevent mineral deposits from your water supply from building up in the unit's
water valve assembly. After ushing with cold water and conrming that there is no
residue in the pipe, install the rubber gasket and tighten the water inlet joint.
DRAWING 04
Nut
Washer
Expansion screw
Heater case