Use and Care Manual

1110
Control Panel
The Control Panel and display are used to adjust the operational settings of the unit
as well as give information about the current state of operation. The following
illustration shows all possible symbols and signs that may appear in various states
of operation. In operation only the symbol or sign corresponding to the actual state
will appear on the control panel display. The water heater is in an operating state
when the hot water temperature is shown.
CONTROL PANEL INDICATIONS
LED display
1. Indicates the “Temperature Set Point” when blinking. Displays the “Actual
Temperature” when the display remains lit.
2. It displays both the “Preset Water Quantity” and the “Actual Water Quantity”.
Combustion” - When lit indicates that the water heater is operating and burning
gas.
“Water valve” - Indicates one of the following three states:
1. No light indicates water heater is operating normally.
2. Blinking: Indicates there is no water flow through the water heater or the water
flow is less than 0.66 gallons per minute (2.5 liters per minute)
3. When on and remaining lit, the firepower of the water heater is operating at either
the minimum or maximum operating point. The actual water temperature may not
reach the preset temperature. The water flow rate needs to be adjusted so the unit
is operating within its capacity range. This will allow the desired temperature to be
reached.
“ºC/L” - Indicates metric units are being displayed (degrees Celsius, liters)
“ºF/G” - Indicates English units are being displayed (degrees Fahrenheit, gallons)
“Up + / Down keys - Used for setting the water temperature and water quantity.
“Mode” key - Used to Set (F4) the water quantity or Display (F3) the water volume
already delivered.
“ON /OFF” key: This button enables or disables the water heater. In the “ON”
mode, the temperature set point is displayed. The factory default temperature
setting is 107ºF (42ºC). In the “OFF” mode, “CL” (Cold) is displayed.
TEMPERATURE CONTROL
Set the Desired Temperature
1. The temperature adjustment range is 95ºF - 149ºF (35ºC 65ºC).
2. Press the “ON/ OFF” key. The temperature display unit lights up and displays the
current temperature set point. The factory default set point is 107ºF (42ºC).
3. Press the “UP” or “DOWN” key to set any desired temperature between 95ºF
(35ºC) and 122ºF (50ºC). The temperature set point goes up or down by one
degree with each press.
4. To set a temperature above 122ºF (50ºC): Press and hold the “UP” key
continuously for about 4 seconds until 131ºF (55ºC) is displayed.
5. Note: When the temperature is above 122ºF (50ºC), each press of the “UP
(DOWN)” key causes the temperature to go up (down) by 9ºF (5ºC).
When the water
temperature is above
95° F (35° C) the
lamps are lit one by
one from bottom to
top.
Failure mode displays
when a failure occurs,
temperature display
mode is switched to
failure display mode.
Switch between
metric and English
units: Press and hold
the “+” and “-”keys at
the same time for
about 3 seconds.
Description of the
mode key F3 current
water quantity F4
preset water quantity