Warranty

2928
Code
Remedy
2. Replace the fusible protection
wire.
E6
1. Mount plug-in wiring properly and
replace bad elements.
2. Replace solenoid valve.
3. Repair or replace the controller.
E8
1. Plug the plug-in element in place,
or replace the bad element.
2.Replace and/or clean Exhaust(air
intake) ducts.
3. Replace and/or clean the vent.
4.Replace the wind pressure
switch.
5.Choose proper location for
terminal installation, and follow the
instruction about Max Vent length to
choose right number of elbows and
length of total vent pipes.
Code
Remedy
2. Check fuel gas supply (especially
when first installed as air pockets
might exist in the gas line. Retry the
ignition process several times).
3. Check if the fuel gas pressure is
too high or too low
4. Replace or repair igniter or flame
detection system.
5.Check the gas type, if the gas type
that the building is supplied with is
not the one indicated in rating plate
on unit, contact the dealer for the
proper unit to match the gas type
E3
Same troubleshooting methods
described in E1.
E4
Normal safety precaution to protect
against a rare occurrence in which
unit is enabled and then the water
flow is dramatically reduced
causing a small slug of very hot
water.
E5
1. Normal system function. This
should be a very infrequent event.
Correct gas or water supply issues
if there are frequent reoccurrence.