EN 0. Contents Contents Safety Instructions 1.
EN Safety Instructions This product shall be protected by a Class A ground fault circuit interrupter. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
EN 2. Mounting Instructions Mounting Instructions EN Mounting Instructions Circuit diagram for PP7, PP8 Electrical installation Outlet Inlet The appliance must be permanently connected to fixed wiring. The device has been prepared for connection to the electrical supply. These units require a 240V, single-phase supply. Please take reference of the rating plate on device. Please take reference of the following diagram to connect power supply with PP7, PP8, PP12 and PP15.
EN Mounting Instructions Circuit diagram for PP15 EN Mounting Instructions Unpacking Check if the device has been damaged in any way.
Mounting Instructions Locate the installation location of the appliance PP7, PP8, PP12 Make sure the clearance meet the requirement of following diagram. Right clearance 4” 8mm / 5/16” Connection to wall Conexión a la pared Left clearance 4” Input electric cable Cable de entrada eléctrico 8mm / 5/16” Right clearance 4” A4. Front clearance 4” Back clearance 1” Front clearance 4” Back clearance 1” Left clearance 4” A3.
EN Mounting Instructions PP7, PP8, PP12 EN Mounting Instructions PP15, PP18, PP24 A7. A8. A11. 6” L1 L2 Push the button to reset the switch L2 208-240V AC L1 1” Outlet A9. A10. Gasket Inlet Filter mat PP15, PP18, PP24 B2. B2. B1. B1.
EN Mounting Instructions PP15, PP18, PP24 PP15, PP18, PP24 B3. B3. B4. B4. B7.a PP15 B8.
EN Mounting Instructions EN The appliance must be grounded properly! The filter mat contained in accessory bag must be installed when connecting with inlet(cold) water pipe or hose! Ground fault circuit interrupter must be installed with the appliance, please take page 17 to 22 for the selection of interrupter. PP15, PP18, PP24 B9. Mounting Instructions B10. Frost The appliance is not to be installed in locations where freezing can occur.
EN Mounting Instructions Commissioning • Fill the device and vent it by opening a hot water tap connected to it. • Only switch on the electrical supply once the device is clear of any air. • Switch on the earth leakage circuit breaker, turn on the appliance and open the hot water tap, wait for about 20 secs before the appliance start working. • Check the operation of the device. For PP15, PP18, PP24 EN Technical Specifications 3.
Technical Specifications Technical specifications EN Technical Specifications Maximum Temperature Rise vs. Flow Rate at 240V POWER PAK Series PP15 PP24 Electric supply 208-240V~ 60Hz 208-240V~ 60Hz 208-240V~ 60Hz Note: Temperature rise = Hot Water Temp. - Cold Water Temp. Flow rate (Δt=65°F) @ 240V 1.6 GPM 1.9 GPM 2.5 GPM Heating system Bare element Bare element Bare element Temperature range 95 - 140 °F 95 - 140 °F 95 - 140 °F Switch on flow rate 0.66 GPM 0.66 GPM 0.
EN 4. User Manual User Manual EN Maintenance 5. Maintenance Operation Maintenance The electronically regulated continuous-flow water heater with automatic temperature adjustment keeps the outflow temperature constant. The device has touch key to switch it on and off, and / keys to adjust the heating. : Decrease the outlet setting temperature; : Increase the outlet setting temperature. This device does not require any maintenance by the user.
EN 6. Troubleshooting Troubleshooting Troubleshooting by users Problem First aid • Check the leakage protection switch and the fuses. • Check if any fittings or shower head are affected by the build-up of lime scale or dirt. • See also “Troubleshooting by users“. Cause Water heater is not heating at all (water is flowing but the unit is not heating - the No power or incoroutgoing water temperature rect wiring. is the same as the cold water supply) - the digital display does NOT light up.
EN Troubleshooting Troubleshooting by users Problem Cause Solution Anti-Scald pressure/ balancing valve or tempering valve. Your faucet may have an anti-scald feature or a tempering valve that automatically mixes cold water even when you turn your control lever or handle to full hot. These devices are usually adjustable so you can turn off the cold mix completely. You can compensate for this by increasing the setting on your water heater if you need/want hotter water.