Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of “going tankless.” Take the time to thoroughly read and understand this safety and installation manual in its entirety before you attempt to install your new Santon tankless water heater, as it contains important safety tips and instructions. Please carefully read all instructions and warnings.
If your water heater requires a reset, be sure to TURN OFF THE BREAKER prior to resetting the unit. Resetting your unit without turning off the breaker can result in personal injury and damage to your water heater. Electrical: Model numbers 7.0kW - 94 805 005 9.0kW - 94 805 006 Electrical rating................................................................. 6.4/7.0kW @ 230/240V ..........................................................................................8.3/9.
MODEL TEMPERATURE RISE AT FLOW RATE IN U.S. GALLONS A.C. ONLY Important Information 0.5 GPM 0,75 GPM 1.0 GPM 1.5 GPM 2.0 GPM 2.5 GPM WATTS VOLTS AMPS WIRE SIZE 94 805 005 95º F 63º F 47º F 31º F 23º F 19º F 7000 240 29.2 8AWG 94 805 006 123º F 82º F 61º F 41º F 30º F 24º F 9000 240 37.5 6AWG AVERAGE COLD WATER TEMPERATURE SUMMER 80°F WINTER 70°F. OUTLET TEMPERATURE EQUALS INLET TEMPERATURE PLUS TEMPERATURE RISE.
3.4. The provision of a service stop valve in the cold supply pipe will assist in the event of any subsequent servicing or maintenance. No non return valve or restriction to be fitted within the mains supply to the heater. strictly followed to safeguard against the hazards affecting life and property during and after installation of this product and during subsequent servicing and maintenance. 3.5.
Preparation 4.11. Remove the unit before soldering the connections. 4.1. Remove the fixing screw which holds the front cover onto the back plate of the Power Pack heater. Carefully remove the cover. 4.12. It is essential to flush the pipe in order to clear debris, particles of solder and swarf. 4.2. The unit must be mounted on a flat surface, which covers the full width and length of the back plate.
6.1. When larger volumes of water are required than can be provided by one heater, multiple installation can be made by connecting a number of heaters in PARALLEL of the cold feed manifold (See Figure 6). This is the ONLY method that is recommended. DO NOT plumb these heaters in series. This unit does not require an Pressure Relief Valve by UL standard, it is recomended that you check with the local codes to find out whether this is required. If one is required please refer to Figure 6. 6.2.
The following comprehensive list of spare parts is available for your Marey Power Pack. Please refer to the rating label on the side of your heater before ordering to ensure the correct spare part is obtained. DO NO REPLACE WITH PARTS NOT RECOMMENDED BY SANTON, AS THIS WILL INVALIDATE YOUR GUARANTEE AND MAY RENDER THE INSTALLATION DANGEROUS. Description Code No. 1. Heat Exchanger Assembly 7.0kW...................................................... 95 606 965 Heat Exchanger Assembly 9.0kW....................