Operating instructions
2
InstallatIon
Introduction
OPERATING ENVIRONMENTAL CONDITIONS
This unit is designed for commercial use and to be safe at 
least under the following conditions:
•  For indoor use only.
•  For use at altitudes up to 6500 ft (2000 m)
•  For use at temperatures from 41°F (5°C) to 104°F 
(40°C).
•  Maximum relative humidity 80% for temperatures up 
to 88°F (31°C) decreasing linearly to 50% relative 
humidity at 104°F (40°C).
•  Main supply voltage uctuations not to exceed ± 
10% of nominal voltage.
•  Transient overvoltages according to Installation Cat-
egories II (in accordance with IEC 664).
•  Pollution Degree 2 (in accordance with IEC 664).
INTENDED USE - DUTY CYCLE
This unit is intended to be operated intermittently. After a 
pre-heat cycle, the longest period of use is 60 minutes. 
The timer allows a maximum of 60 minutes. After each 
use the unit should be opened for removal and reloading 
of product. The water level should be checked after each 
use and relled when necessary.
SERVICE & TECHNICAL INFORMATION CONTACT
   WARNING
This unit should be serviced by qualied ser-
vice personnel only.
Your Sterilmatic Sterilizer has been developed to answer 
the need for a compact, automatic, low-cost steam pres-
sure sterilizer. The following instructions cover installa-
tion. Should service be required, it is readily available by 
contacting our authorized service agency located nearest 
to you. The name of your local service company can be 
obtained on our website, www.mi.com.
WATER CONDITIONS
Market  Forge  from  time  to  time  is  asked  the  question 
about using distilled or deionized water for use with our 
Sterilizer models STM-E and STM-EL. We are always 
asked why these water choices are not allowed for use 
with our units and what would be recommended. To ad-
dress this situation, we have complied the following as a 
means of satisfying these questions:
1.  We have found that the use of distilled or deionized 
water will aggressively attack the pure coat of Alumi-
num Alclad, which protects the bottom surface from 
oxidizing and then eventually pitting (reference: Op-
erating and Maintenance Instructions).
2.  In addition pitting can also be caused by several other 
external environmental factors. Few examples are as 
follows. These conditions have been highlighted in 
our documentation.
•  Grains of hardness in the water supply should 
be as follows (.25 to 2).
•  A pH imbalance in the water supply can greatly 
affect the life to the aluminum cylinder. The pH 
range that would be recommended is between 
7.0-8.5.
•  The lack of a positive electrical ground can 
cause an electrolytic reaction that will accelerate 
pitting.
•  Another contribution to accelerate pitting is the 
type of cleaning solutions used or the abrasive 
scrubbing pads. If a low pH is present with the 
detergents being used or an abrasive pad, the 
protective Alclad coating will be removed during 
the cleaning process.
•  Spillage of media being sterilized can also con-
tribute to the accelerated pitting if it is corrosive.
•  CHLORINE LEVEL ≤ 1 PPM.
 IMPORTANT
Market Forge will not be responsible for dam-
age resulting from the use of hard or corro-
sive water, from failure to drain the unit daily, 
or from inadequate cleaning procedures.










