11. FITTING THE PROBE – STANDARD TRANSMITTER
11.1 Fitting the probe – standard transmitter
To fit or remove the transmitter probe proceed as follows:
Warning:
When fitting the probe make sure that the O-rings are in excellent condition and are correctly positioned in their seats.
T25/TL25/TT25 PROBE
- screw the flange (A) onto the transmitter with the wrench (A1);
- screw the probe onto the flange (A) with the wrench supplied (A2).
T36 PROBE
- secure the probe to the flange (B) with the screws (B1);
- screw the flange (B) to the transmitter with the wrench supplied.
T60/TT60 PROBE
- secure the probe to the flange (C) with the screws (C1);
- screw the flange (C) to the transmitter with the wrench supplied;
Warning:
When the operation is complete, align the system.
Figure 11-1
A
2
A
T25/TL25/TT25
B1
B
T36
C1
C
T60/TT60
A
1