SPA COVER
When the spa is not in use, the cover should be kept on the spa to retain the
water’s heat and to keep out dirt, leaves, etc.
For your safety and convenience, the cover is equipped with adjustable straps,
safety locks, and handles. Use the exterior handles to remove and replace your
cover. Never attempt to open or remove the cover by grasping or pulling on the
cover skirting or cover lock straps as the skirting will tear.
Marquis suggests you use the safety locks to help keep out unintended users
and prevent covers from being blown off in windy conditions. The cover and
retractable cover system are not recommended for use in wind conditions
reaching above 40 km/h. If your spa is located in an area susceptible to high
winds, additional cover lock straps may be necessary to minimize cover
damage.
Open the spa cover:
1. Unfasten all cover lock straps.
2. Place one hand under the cover skirting, between the spa and cover,
to break the cover’s vacuum seal. Do not use cover handles to break
vacuum seal.
3. Fold the front half of the cover over onto the back half.
NOTE: Unlock and release all cover locks before attempting to open cover.
Damage caused by attempting to open the cover while locked or by wind is not
covered under warranty. Do not walk, stand, climb, or sit on the vinyl cover or
retractable cover system. Do not use hard, sharp, or metal objects, such as a
windshield scraper, to remove ice. Such objects can cut, mar, or puncture the
cover’s vinyl surface.
Close the spa cover:
1. Place one hand on the upper corner of the cover and gently push
forward in the direction of the spa. The cover will rotate forward to
cover half of the spa.
2. Unfold the cover by lifting the handle located on the top (front) half of
the cover. Allow the unfolded half to fall down onto the spa.
3. Secure the cover lock straps to the spa and lock them.
NOTE: When opening a cover with a cover removal mechanism, use one of the
manufacturer’s recommended methods. Do not attempt to open the cover in any
other way. Damage caused by improper opening or closing of the cover is not
covered under the warranty.
Fading, staining, torn stitching of the spa cover and broken foam cores are not
covered under the warranty if caused by improper use or maintenance. Spa
covers do not qualify for labor coverage under the warranty. These parts can be
purchased or exchanged under warranty at your authorized Marquis Spas®
dealer.
SPA CONTROL OPERATION
Destiny, Envy, Epic, Euphoria, Mirage, Promise, Rendezvous, Resort,
Reward, Spirit, Wish
PUMP PRIMING (Pr)
Pump priming feature begins at start-up. When your spa is energized, the LCD
window displays a “Pr” message. This mode lasts approximately four to five
minutes, if not exited manually by pressing the TEMP pad.
UNDERWATER LIGHT
Press the LIGHT pad on bather’s panel to turn the underwater light on and off.
After being on for 60 minutes, the light automatically turns off.
COLORED LIGHTS AND TWILIGHT SYSTEM
Use SPA LIGHT pad. Step one: turn on light. Step two: turn off and then on
within 2-3 second time period. Repeat for all colour options.
WATERFALL FEATURE
The water flow is controlled by an independent valve.
JETS
Use the JETS pad on the bather panel or remote control. First press of the JETS
pad activates pump on low-speed (and starts soak timer). Second press of the
JETS pad activates pump on high-speed. Third press of the JETS pad turns jets
off for all-quiet mode. Fourth press of the JETS pad turns pump back to low-
speed. If the pump is already on low (heating, filter cycle) then the first press
starts the soak timer. After running on low- or high-speed for 15 minutes, the
pump automatically turns off (unless in heating or filtering cycle).
SOAK TIMER
The soak timer starts the first time you press a JETS pad. The LCD window
displays the elapsed time (1-30 minutes) for 55 seconds, then switches to the
current water temperature for five seconds, then back to the timer. It continues
to alternate for the entire 30 minutes. The timer runs for 30 minutes regardless
of other functions in use (jets, temperature, or light). You can manually cancel
the timer by pressing the TEMP+- pad and then the LIGHT pad.
SOLID-STATE OZONATOR (OPTION)
The ozone generator functions whenever the system is running on filter or clean
up cycles. You should occasionally inspect your ozonator to ensure it continues
to light.
FILTRATION SYSTEM
Your spa is preset at the factory with a default setting to filter itself using the jet
pump on low-speed for two hours twice in a 24-hour period. These settings
represent the filter settings necessary for average use. The timing of the first
filter cycle is determined by when the spa was initially energized. The first cycle
begins six minutes after this initial power-up. The second filter cycle begins 12
hours after the first cycle.
Factory Default Settings:
• Filter Cycle Duration: F2 (2 hours)
• Filter Cycles: 2C (twice per day)
• Cleanup Cycle: 1H (1 hour)
These settings represent the most commonly used settings, but your use may
be different, depending upon many variables – frequency, number of bathers,
duration, water capacity, etc. These variables affect the quality of water and the
way it should be managed to achieve the most effective cleansing. Selectable
choices for the settings of the operation systems allow flexibility and ensure your
spa remains easy to maintain for your particular set of circumstances.
To adjust the filter settings
Press the SETTING pad to display the filter time settings (F1, F2, F4, F6). Use
the TEMP+- pad to scroll through the options. When desired selection has been
reached, press the SETTING pad again to enter selection and advance to the
filter cycle settings (2C, 1d, 1n). For example, if you select 2C and F2, your spa
will filter two hours twice a day for a total of four hours of filtration daily.
Use the TEMP+- pad to scroll through filter cycle options. When desired
selection has been reached, press the SETTING pad to enter selection and
advance to the smart logic settings.
Selectable filter cycles and cycle duration
2C: twice per day (once every 12 hours)
1d: once during the day
1n: once during the night
F1: 45 minutes
F2: 2 hours
F4: 4 hours
F6: 6 hours
5