Owner`s manual

M A R Q U I S S P A S
®
OWNER’S MANUAL
FILTRATION SYSTEM
Since a spa is always covered when not in use, it stays fairly free of debris or
outside contamination. Contamination to a spa’s water occurs during usage, so
filtering immediately after usage is the most effective time to clean the spa
water. Your spa is preset at the factory with a default setting to filter for one hour
(1H) every time your spa is used. This filtration cycle begins 30 minutes after the
spa light or jet pump has been deactivated. The pump runs on low-speed to filter
the water for the cycle’s duration.
Selectable Settings
1H: 1 hour
2H: 2 hours
3H: 3 hours
4H: 4 hours
• OH: Off
To Adjust the Filtration Settings:
Use the TEMP+- pad to scroll through options. When desired selection has been
reached press SETTING pad to enter selection and exit settings mode.
TEMPERATURE DISPLAY AND ADJUSTMENT
Factory Default Settings:
• Temperature: 39°C
The LCD window displays the actual water temperature. Pressing the TEMP+-
pad makes the numbers flash, then pressing the pad again (repeatedly)
increases the set temperature one degree at a time, up to 40°C. After a short
pause, the actual temperature displays. Press TEMP+- pad repeatedly to
decrease the set temperature to 27°C.
HEAT MODE
Your spa comes preset in the standard heat mode. For most applications, the
standard mode should be used. If you are in a warm weather climate and the
spa does not require as much heat, the economy mode may work best. For a
vacation home or for very infrequent use, the sleep mode provides filtration and
circulation with lower energy demand. In economy mode your spa heats only
during the filter cycle. In sleep mode your spa will maintain a water temperature
that is 20°F (7°C) below the set temperature. This ensures your spa will be
ready to use more quickly (allow about one hour per one degree F for heating
your spa’s water) when increasing the temperature to the desired level.
The spa’s heat mode can be adjusted to one of three different settings:
Standard Mode
The spa water heats to the temperature as set at the bather’s panel. In this
mode, the filtration pump turns on for two minutes every half-hour to “poll” or
check the water. If heat is needed, the unit heats to the set temperature. The
LCD window steadily displays the actual temperature in this mode.
Economy Mode
In this mode, the spa only heats to the set temperature during a filter cycle. The
LCD window displays “Ec” alternately flashing with the actual temperature when
the spa is up to temperature and “Ec” steadily when the water temperature is
below the set temperature.
Sleep Mode
Your spa will maintain a water temperature that is 7°C below the set
temperature. The heater functions only during a filter cycle. The LCD window
displays “SL” flashing alternately with the actual temperature when the spa is up
to set temperature and displays “SL” steadily when below set temperature.
To Adjust the Heat Mode:
First press the SETTING pad to display the heat mode settings (St, Ec, SL). Use
the TEMP+- pad to scroll through the options. When desired selection has been
reached, press SETTING pad again to enter selection and advance to the filter
cycle settings (F1, F2, F4, F6).
HEAT LIGHT
The HEAT light illuminates when the heater is on. The pump circulates on
low-speed whenever the thermostat calls for heat.
SYSTEM LOCK
Once you find and establish the settings that work best for your individual needs,
use system lock to keep from inadvertently changing the settings.
Press the TEMP+- pad and then immediately press the SETTINGS pad.
Unlock by repeating sequence. While the system is locked, you may still operate
the jets and light. The LCD window displays LC to indicate the system is locked
when you try to change the temperature or settings.
SPA CONTROL OPERATION
Show
Epic
PUMP PRIMING (Pr)
Pump priming feature begins at start-up. When your spa is energized, the LCD
window displays a “Pr” message. This mode lasts approximately four to five
minutes, if not exited manually by pressing the TEMP+ pad.
UNDERWATER AND ENTRYWAY LIGHTS
Press the LIGHTS pad on the bather’s panel or remote control (option) to turn
the underwater and Entryway lights on and off. The icon appears in the lower
center of the display when the light is on. The low-voltage system produces a
night light for evening use. After being on for 60 minutes, the lights automatically
turn off. See SETTINGS for automatic light programming.
AQUA AMBIANCE™/CONSTELLATION™
Press LIGHTS pad to turn on step one. Press LIGHTS pad again to turn off for
one second. Then press LIGHTS pad again for step two. Repeat for all options.
WATERFALL TRAY FEATURE (option)
The waterfall feature and convenience tray attaches securely to the dual Vortex
skimmer tops. NOTE: Don’t remove the waterfall top while the pumps are
running. The tray feature on the Show spa attaches to the spa interior.
SOAK TIMER
The soak timer starts the first time you press the TIMER pad. The LCD window
displays “E” for the elapsed time followed by time in minutes (“00, 01, 02”, etc.).
A second press of the TIMER pad will exit the timer mode. The timer display and
the current temperature display will alternate every 10 seconds.
SETTINGS
Clock
Press the CLOCK pad followed by the SETTING pad. “Program” will be shown
in the upper left corner of the panel display and the hour will begin flashing. To
adjust, press the TEMP+ or TEMP- pad. Once the correct hour has been set,
press SETTING pad to set the minutes. “Minutes” will flash. Follow above
procedure to set the correct minutes.
Filter Cycle 1:
Press the CLOCK pad followed by the SETTING pad three times to enter Filter 1
programming. “Program filter 1 start time” will be shown in the upper left corner
of the panel display and the hour will begin flashing. To adjust, press the TEMP+
or TEMP- pads. Once the correct hour has been set, press SETTINGS pad to
set the minutes. Follow above procedure to set the correct minutes. Press the
SETTING pad again and “Program filter 1 end time” will be shown in the upper
6