\Çy|Ç|àx fxÜ|xá Installation Instructions Model Number: Stock Numbers: MQRB5143 MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE Certified to: ANSI Z21.50-2007, ANSI Z21.50a-2008 CSA 2.22-2007, CSA 2.22a-2008 This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. “Zero Clearance” Direct Vent Gas Fireplace Read this complete manual before beginning installation.
Table of Contents Table of Contents ................................................................................................................................................................................... 2 Pre-Installation Questions and Answers................................................................................................................................................. 5 Why does my fireplace or stove give off odour?..............................................................
Installers Note: ................................................................................................................................................................................. 28 Gas Line Installation............................................................................................................................................................................. 29 Gas Specifications..................................................................................................
Infinite Wall Surround-(Covers 55-3/4"W X 24") ............................................................................................................................... 54 Infinite Porcelain Liners .................................................................................................................................................................... 54 Accessories ................................................................................................................................
Pre-Installation Questions and Answers Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installation (e.g. marble, tile and the adhesives used to adhere these products to the walls can react with heat and cause odours).
Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada. Figure 1 - Mobile Home Installation.
Installation and Operation Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.
13. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. 14. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of glass should be done by a licensed or qualified service person. 15. Do not operate appliance unless completely installed as per installation instructions. 16.
MQRB5143 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to right side of unit.
Surround Dimensions MQRB5143 • • • The Surround Frames are 1” thick, with a 3/4” space behind the frame. When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”. The Fireplace may be covered up to within 1/2” of the Fireplace Opening with non-combustible materials.
MQRB5143 Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance. Failure to comply with those requirements can seriously compromise the safety and operation of the fireplace. Specifications 1.
MQRB5143 Nailing Tab Guide [Qty]2 Nailing Tabs are located on each corner of the fireplace. The Nailing Tabs on the MQRB5143 can be used in two ways: Framing Flush with Face of Fireplace -Fireplace to be covered with Non-Combustibles (e.g. Concrete Board) for Flat Wall appearance. 1/2” Drywall Flush with Face of Fireplace –Fireplace and Combustible Wall to be covered with Non-Combustible Materials (e.g. Tile around Fireplace).
MQRB5143 -See Thru Framing An MQRB5143SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance). Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”.
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. [Steel Stud Framing Shown.] *See the “Nailing Tab Guide” and “MQRB5143SK” pages before placing unit into the framed opening.
MQRB5143 Single Sided Framing An MQRB5143BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance).
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. [Steel Stud Framing Shown.] *See the “Nailing Tab Guide” and “MQRB5143BK” pages before placing unit into the framed opening.
MQRB5143 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and insulation material to prevent direct contact with the appliance. See Thru or Single Sided Installation [Steel Stud Framing Shown.] Single Side Installation Only [Steel Stud Framing Shown.
MQRB5143 Facing Material Requirements These specifications are the same for all Models (5143N, 5143NE, 5143LP, 5143LPE). Note: If using Optional Surround, See Surround Clearances Section. [Steel Stud Framing Shown.] Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged. Steel Stud Framing Shown.
MQRB5143 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantels to consider: Combustible and Non-Combustible. A Combustible Mantel is one that consists of material(s) that may discolor, combust, or lose its integrity in the presence of heat. These types of mantels must strictly conform to the dimensional requirements shown below.
MQRB5143 Finishing Options Using Side Fillers The Side Fillers are located at each side of the door. They are provided to give a continuous surface up to the opening of the fireplace door. Using other Non-Combustible Materials as Side Fillers (Brick, Tile, Marble, etc.) Non-Combustible facing materials, such as brick or tile may be used in place of the Side Fillers- so long as the total amount of material applied is not thicker than 1-1/2” on the inside of the fireplace opening.
MQRB5143BK Back Shield Kit –Single View *This Kit must be opened before unit is installed into Framing (See “Single Sided Framing” page of this Manual). Contents of Kit: Firebox Cover Heat Shield Assembly Back Liner False Bottom Small Tube Millpac (Qty)45- DT Screws Heat Shield & Firebox Cover Before placing fireplace into framed opening, you must install the Firebox Cover and the Heat Shield Assembly onto the back of the unit.
Back Liner, False Bottom, and End Panel Installation: 1. Remove Liner Clips from the inside of the Firebox. 2. Place the Back Liner into the Firebox with bends facing the Rear Firebox Cover. 3. Next install the False Bottom with larger Dimension to Front Glass Opening (See Right), and secure it with 6 DT screws into the mounting tabs on the Burner Tube. 4. Place End Panels on top of the False Bottom and tilt into place at either end of the Firebox. Replace the Liner Clips.
MQRB5143SK (See Thru Kit) Installation This basic Kit is required for See Thru installations. Note: If you wish to cover the Side Fillers with non-combustible materials, they must be installed before Facing materials are applied. Components: [2ea.] Side Fillers Valve Access Cover Glass Door c/w Glass See Thru False Bottom [4ea.] #6 Black Screws [6ea.] ¼” DT Screws Installation Procedure: 1. Side Fillers Place Side Filler onto Side of Fireplace opening. Attach with [2] #6 Screws provided.
MQRB5143 Surround Installation The Surround Kits for the MQRB5143 are available in 3 different finishes: Surround Kits: Small [1-1/2”] Large [4”] MQRB5019SBL MQRB5019SSS MQRB5019SPW MQRB5624SBL MQRB5624SSS MQRB5624SPW -Black -Stainless Steel -Pewter Each kit contains: (Qty-1) Surround Frame (Qty-2) Surround Side Fillers (Qty-1) Surround Access Cover (Qty-6) #6 Self Tapping Screws The Surround Frames are 1” thick, with a ¾” space behind the frame.
Optional Additional Screws: Stainless Steel Surrounds Two additional screws may be added to MQRB5019SS and MQRB5624SS to counteract heat distortion. Directions: 1. Install Surround normally as per Instructions. 2. Drill a pilot hole through the unused slot in each corner of the inner top of the surround. 3. Insert Screw.
Optional Glass Ember Installation If you wish to use this media evenly spread the glass embers onto the false bottom and burner. Ensure the glass embers do not excessively overlap as this will affect the flame pattern. (MQG5W) 5 lbs of ½” White Ember Glass is supplied with every unit. Use care when placing glass embers near the pilot area so as not block or have the glass fall over the crossover holes from the pilot to the burner, as delayed ignition can occur.
Door and Glass Information Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass, and causes dust, lint etc. to cling to the glass surface. Also, initial paint curing can deposit a slight film on the glass. It is therefore recommended that initially the glass be cleaned two or three times with non abrasive common household glass cleansers and warm water.
Valve Access Cover Removal Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert fingers into holes in Access Panel and lift out. When replacing Access Panel, engage Tabs into Slots in Bracket. MQRB5143 Removable Lower Face Panel Installers Note: Once the installation is complete attach the Lower Face Panel. Insert two [2] screws on each side and seven [7] screws at the bottom of the Lower Face Panel. Place on the Valve Access Cover.
Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A. 1. The gas pipeline can be brought in through either the left side or the bottom of the appliance. A knockout is provided at either location to allow for the gas pipe installation and testing of any gas connection. 2.
Millivolt System, Lighting, and Burner Control 30
Troubleshooting the Millivolt Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Spark igniter will not light. Pilot will not stay lit after carefully following lighting instructions. Pilot burning, no gas to burner, valve knob “ON”, and wall switch “ON”. Possible Causes Corrective Action Defective or misaligned electrode at pilot.
MQRB5143 Gas Conversion or Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE.
Gas Conversion for Top Convertible Pilot (Series 019065X) Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer. 1. Shut off the gas supply to the appliance. 2. Allow the pilot burner to cool to room temperature.
MQRB5143 Burner Tube Removal 1. 2. 3. Remove the six [6] DT screws from the lower portion of the Burner Tube Mount Brackets. Slide the Burner Tube away from the Plumbing Connection until it disengages from the orifice. Reverse these steps to reinstall. MQRB5143 Burner System Removal/Installation Guide -WarningTurn off Unit and allow to cool before cleaning. Only a Qualified service technician should service and repair this appliance. 1. Lift off Valve Access Cover. Remove Valve Heat Shield. 2.
Moving Valve to Other Side of Fireplace The Valve Assembly may be changed to the other side of the fireplace. This must be done Before the unit is inside the enclosure. 1. Remove the Burner Tube (See Burner Tube Removal section in this Manual). 2. Disconnect plumbing from the valve, including connections to Pilot. Remove the [4] DT screws in the burner pan which hold the Valve System in place. Reinstall with the Valve System on the other side of the fireplace. Reconnect plumbing, along with Pilot.
IPI Electronic Ignition System SYSTEM NOTE In the event of an operational lockup the IPI system must be reset by removing the batteries from both the backup pack and the remote receiver module. Remote Receiver Location -For All IPI Installations & GT Series Remotes OnlyThe Remote Receiver may be located outside of the unit- up to a maximum of 6 feet from either side of the fireplace. An Extension Harness (Part No. 1001-P904SI) is required.
Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A. This fireplace is equipped with an ignition device which automatically lights the pilot. Do not try to light by hand. B.
IPI Electronic Ignition Parts List – Standard System Item No. Part No.
LK2 Halogen Lamp Kit Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. SYSTEM NOTES 1. Each lamp is running on a dedicated circuit (Parallel circuit). This means that if one bulb fails the rest will remain operational. 2. Rocker switch is switching low voltage side. 3. Solid-state transformer is designed to run halogen lamps ONLY. 4.
Photos Bottom of Unit with IPI Module Light Module &IPI Valve 41
Close up View of IPI Module Inside of IPI Module 42
IPI Valve IPI Valve 43
Millivolt Valve & Light Module Millivolt Valve 44
Venting A. B. C. D. E. F. G. H. I. Clearance above grade, veranda, porch, deck, or balcony 12in [30cm] min.[1,2] Clearance to window or door that may be opened. 12in [30cm] min. for appliances 100,000BTUh [30kW] and lower, in Canada. 9in[2] [23cm] for appliances 50,000 BTUh and lower, in USA. [2] Clearance to permanently closed window min. 12in [30cm] recommended to prevent condensation on window, in Canada. 9in [23cm] for appliances 50,000 BTUh and lower, in USA.
General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) venting kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson Dura-vent Direct Vent system (Model DV-GS Series), and AmeriVent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
Figure 2 - Flex pipe spring spacing guide. Horizontal runs require support metal straps every 2ft. In an offset installation support straps should be used to stabilize pipe. Expand 5" and 7" flex pipe to the point that the 7" protrudes approximately 2 to 3 inches past outer wall and the 5" flex protrudes approximately 2 to 3 inches past the 7" flex. Attach the 5" pipe to the termination first and secure with sealant and [4] screws then attach the 7" flex to the termination with caulking and screws.
Minimum clearance to combustibles on venting is 1” with the following exceptions: -Top of horizontal is 2”. -Top of 90 degree elbow in an enclosure under 72” is 5” with Wall Thimble Shield [Z57WTS]. -Top of 90 degree elbow in an enclosure over 72” is 4”. -Minimum Enclosure Height is 60” (See “Enclosure Heights” page in this Manual). -Minimum Termination Height from bottom of Unit is 51-1/2” plus ¼” rise per foot.
Venting Examples All horizontal runs have a minimum ¼” rise per foot.
Installation of Side Wall Venting The minimum distance from the bottom of fireplace to centre of vent is 51-1/2". For combustible walls: Cut a hole through the wall allowing for an 11" x 11" (inside dimension) wall thimble. For a non-combustible wall: Cut an 8" diameter hole (see Figure 4). Note that the clearance to combustibles is stated the Clearance to Combustibles section of this Manual.
Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney (see Figure 7a). When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1" spiral nails.
Flue Restrictor Adjustment MQRB5143 –All Models The Flue Restrictor is located in the top of the Firebox in front of the Flue Opening. For vertically vented installations it is necessary to use the Flue Restrictor. Restrictor is set fully open from factory for short horizontal and vertical runs. To adjust the Flue Restrictor: Fig.1 1. Remove the [2] DT screws in the Flue Restrictor. Also remove the [2] screws at the front of the Flue (Fig.1). 2. Rotate the Flue Restrictor 180°. (Fig.2).
2” Top of Horizontal Vent Figure 6 - Clearances in horizontal venting. Figure 7 - a) Straight-through roof support configuration; b) Flex bend configuration; c) Termination mounting.
MQRB5143 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -51” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Burner, Two Sides Open, SIT Valve with Hi/Lo Flame and BTU Adjustment, Ceramic Glass, 5/7" Flue, Wall Switches, Junction Box, Accent Lighting with Decorative Ember Glass, 40,000 BTU MQRB5143N Linear Multi-Sided Fireplace, Milli Volt Valve (as above) Natural Gas MQRB5143LP Linear Multi-Sided Fireplace, Milli Volt Valve (as above) Liquid Propane MQRB5143NE Li
MQG5W Decorative Ember Glass - White - 5 lbs MQG5B Decorative Ember Glass - Black - 5 lbs MQG5T Decorative Ember Glass - Turquoise - 5 lbs MQG5C Decorative Ember Glass - Copper - 5 lbs Electronic Ignition GFRC Remote Control Millivolt/IPI - On/Off GTRC Remote Control Millivolt - Thermostat GTMRCN Remote Control Millivolt - Thermostat/Modulating - NG GTMRCP Remote Control Millivolt - Thermostat/Modulating - LP EGTRC Remote Control IPI - Thermostat EGTMRCN Remote Control IPI - Thermostat/Mo
1000-215 Pal Nut (18MMXI.5MM) BLK (1364.03) 1000-218 Switch Ivory (1451/001) 1000-227 Cover Ivory (86001/001) 1000-255 Orifice Brass -(State Size) 1000-306 Thermalcord -Adhesive Back for Door Frame 5143ZDV-311 Ceramic Glass –For All MQRB5143 36HB-123 Upper Door Spring Venting Accessories Z57HSK5 Horizontal Round Termination Vent Starter Kit - 5/7" X 5 FT Length, Wall Thimble Shield, Horizontal Vent Termination, Wall Thimble, 60" Flex Pipe, Screws, Mill Pac.
Warranty 57