Install Instructions

Product Description
The Azure
®
Hand Held Programmer allows the Azure
®
Digi-Motor
®
(MARS No. 10860/10861) to be custom speed
tuned to each application. Although the motor performs an auto sizing function that will correctly assign torque to
each of the speed taps for the installed application, there may be instances when custom speeds are desired.
Allows blower speed to be reduced to the low end of CFM tolerance for improved dehumidification.
Allows duplicate speeds to be set on multiple speed taps.
Allows CFM to be maximized especially in high altitude applications.
• Provides speed tap flexibility for multi-stage systems.
Connections
These instructions assume the Azure
®
motor has already been properly installed, auto sized, and the necessary
speed taps have been connected.
1) Remove power to the HVAC system.
2) Plug the BROWN/WHITE harness on the programmer into the BROWN/WHITE harness on the Azure
®
motor.
3) Connect the RED power clip on the programmer to +24V (R on thermostat).
4) Connect the BLACK power clip on the programmer to 24V (C on thermostat).
WARNING!
To prevent electric shock, personal injury, or death, turn off the electric power at the disconnect or main service panel prior to
making any electrical connections.
Installation Instructions
MARS No. 08502
Azure
®
Hand Held Programmer
www.marsdelivers-contractors.com
98886
Operation
When powered and connected to an operational Azure
®
Digi-Motor
®
, the programmer will provide a digital display of
the % of max motor torque being applied by the speed tap that is energized on the motor. This figure is a direct
correlation to motor speed and serves as a point of reference when increasing/decreasing and setting motor speeds
on any of the taps.
1) Apply power to the system. If the blower is not running, the programmer will display ‘--‘. If the blower comes on,
the programmer will immediately display the % of torque on the energized tap.
NOTE: The programmer can only adjust one speed tap at a time. The speed tap must be energized. In order to
read and set the speeds, one of the following procedures should be followed to energize the speed taps:
(continued on back)