User guide
Engineer 418 & 818 User Manual  Page 23 
Connection instructions for Phoenix terminal blocks 
To connect the Phoenix terminal blocks, always use the following procedure: 
  strip the jacket 20mm 
  strip the wires 7 mm 
  in case of stranded wires, pre tin the wires 
  cover the ground wire with a heat shrink sleeving 
  put the wire up to the plastic sleeve in the terminal block 
  use a small flathead screwdriver to firmly close the contact 
  make a strain relief so no stain is on the connection 
  for suitable wire thickness, please refer to the table below 
Conductor cross section solid min.  0.2 mm
2
Conductor cross section solid max.  2.5 mm
2
Conductor cross section stranded min.  0.2 mm
2
Conductor cross section stranded max.  2.5 mm
2
Conductor cross section stranded, with ferrule without plastic sleeve min.  0.25 mm
2
Conductor cross section stranded, with ferrule without plastic sleeve max.  2.5 mm
2
Conductor cross section stranded, with ferrule with plastic sleeve min.  0.25 mm
2
Conductor cross section stranded, with ferrule with plastic sleeve max.  2.5 mm
2