Engineer 418 & 818 User Manual  Page 46 
The output channel tab 
All output settings are grouped on a per-channel base within the output tab. You can access this through the 
output settings tab or from the main routing screen by pressing the corresponding button in the routing 
overview. 
Each output channel features an eight-band parametric EQ, crossover filers, polarity, delay and gain settings 
and an output-limiter. The EQ and crossover filter settings can be switched from the top-right part of this tab. 
A specific type of filter and the settings that go with it can be changed from the “filters” overview that can be 
expanded and closed using the vertical bar to the right of this view.  
The following types of EQ filters are available: 
  Bell filters 
  Low-shelving filters 
  High-shelving filters 
  Band-pass filters 
  Band-reject filters (notch filters) 
  2
nd
 order allpass filters (effects phase only) 
  Filter bypass (no filter) 
Crossovers can also be selected from a range of flavours: 
  2
nd
 or 4
th
 order Linkwitz-Riley (12dB/Octave or 24dB/Octave) 
  1
st
, 2
nd
, 3
rd
 or 4
th
 order Bessel (6dB/Octave to 24dB/Octave) 
  2
nd
, 3
rd
 or 4
th
 order Butterworth ((12dB/Octave to 24dB/Octave) 