Manual

DMX contro
l
19
Channel 1 DMX value
range
Function Macro description Default
value
Haze
output
Level
0-19 Idle range None 0
20-29 Haze 5%
30-39 Haze 10%
…….. …….
210 -255 Haze 100%
Channel 2 DMX value
range
Function Macro description Default
value
Fan
output
level (fan
will always
run if haze
is active)
0-19 Idle range None 0
20-29 Fan 5%
30-39 Fan 10%
…….. …….
210 -255 Fan 100%
Channel 3 DMX value
range
Function Macro description Default
value
Special
functions
0-50 Idle range None 0
51-100 Prime 5 seconds within
range to activate
once
101-150
A
uto Fan
mode
None (level
triggered)
151-200 Heater off &
shutdown
5 seconds within
range to activate
once
201-255 Heater on
(normal
operation)
None, but heaters
will stay on if
channel 3 returns to
zero
Note that when the heaters are on, Channel 3 can stay at level 0 without affecting
the operation of the machine.
This means that Channel 3 need only go to 100% once at the start of a show,
then it can assume a default of zero without the heaters turning off, thus ensuring
that the machine is ready when the show runs again. To turn the heaters off, use
the Heater Off macro.