Manual

Basic service 21
Basic service
Before servicing the Jem Compact Hazer Pro™, read and observe all the
precautions listed in “Safety information” on page 4. Any service not
described in this section must be carried out by a Martin service technician.
Cleaning
Excessive dust, haze fluid, and dirt build-up will degrade performance and cause
overheating and damage to the machine that is not covered by the product
warranty. To maintain adequate cooling, dust must be cleaned from the outer
casing and air vents of the machine periodically.
Isolate the machine from power and allow to cool completely before cleaning.
The haze output nozzle remains hot for a period after use.
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
Clean haze fluid residues from the haze output of the machine using a
damp cloth.
Clean the outer casing with a damp cloth only.
Fuse replacement
The two fuses for the haze machine are located on the electronics board inside
the unit.
DANGER! Disconnect the power supply before removing any covers. Live
parts inside!
To replace a fuse, disconnect the power cord from the supply, unscrew the
screws holding the top cover of the unit and remove the cover. The electronics
board is located in the compartment under the display.
Remove the spent fuse and replace with one of exactly the same size and rating.
The fuse type is indicated below. Contact Martin Service if the fuse blows
repeatedly.
F1
120V = 10AT
230V = 6.3AT
F2
120V = 3.15AT
230V = 3.15AT