Troubleshooting
Problem Probable cause(s) Suggested remedy
Machine will not produce
haze when control panel set
to RUN or remote control
Haze switch turned on
Machine not at operating
temperature
Wait until  message
no longer shown
 set to 0 Increase setting
 set to 0 Increase setting
DMX signal present
Disconnect or turn off DMX
controller
Machine can be fired from
control panel or remote
control, but not by DMX
controller
DMX address setting
incorrect
Change DMX address (page
14)
Poor connection in DMX line
Check DMX cables and
connections
LINK menu is set to SEND Set LINK menu to RECV
Haze output is weak Machine requires priming Prime machine (page 15)
Wet, greasy, non-uniform
haze output, fluid drips or
spits from nozzle, or very
loud noise when firing
machine
Incompatible haze fluid Use approved fluid!
Machine appears dead
Mains fuse blown Replace fuse (page 21)
No power at AC cable inlet
Check power cable and
circuit breaker
Machine causes DMX errors
to occur on other units when
connected to a DMX system
LINK menu is set to SEND Set LINK menu to RECV