Operating Instructions

BDA Captura 100 MIFARE® / 2020-10-26 (GB)
16

Hold the master card
in front of the lock.
Hold the programming
card “P2: Sound“
in front of the lock.
The acousc signals are
deacvated.
Acousc signals are deacvated
Hold the programming
card “P2: Sound“
in front of the lock again.
The acousc signals are
acvated again.
Acousc signals are acvated
Hold the master card
in front of the lock.
DEACTIVATING AND ACTIVATING ACOUSTIC SIGNALS
Acousc signalling is acvated when the system is delivered. You have the opon of deacvang the acousc
signals with the aid of the master card and the programming card “P2: Sound“. For this, the lock must be open.
It is recommended that the acousc signals should only be deacvated if the RFID reader with the LED is mounted
outside the item of furniture. Otherwise, neither visual nor acousc signals are passed on to the users, making
programming and possibly also operaon dicult.
Please note that the acousc signals for the baery warning and for changing the operang mode cannot be
deacvated.
The programming card set must be bought separately from LEHMANN Vertriebsgesellscha mbH & Co. KG.
The cards are for universal use.

If a reset to factory sengs is required, all master and user cards are deleted. With an installaon card the basic
funcons (close and open) can be carried out. The bolt is retracted, and the lock must be reprogrammed with a
master card.
The reset funcon can be used with the help of the master card and programming card
P3: Reset“. For this,
the lock must be open. The programming card set must be bought separately from LEHMANN Vertriebsgesellscha
mbH & Co. KG. The cards are for universal use.