System Description

BDA M410 TA03 / 2019-09 (GB)
18
AUTOMATIC LOCKING IN FIXED CODE MODE
The lock must be in open posion. There must be no baery warning. This feature can only be acvated in Fixed
Code mode. If you have already changed the default master code, enter your valid master code here. In order to
conrm the master code, press the keys
x
+
simultaneously.
Select the me span aer which the lock is to close automacally.
Note that there may be slight variaons in the me span. A second-exact measurement is not possible. When swit-
ching to the Free Code mode, this funcon is automacally deacvated.
Enter of master code (example: factory sengs)
Keys
9
0
8
0
7
0
5
5
5
5
x
+
Display
The lock is in conguraon
mode (connuous green
light).
simultaneously
Keys
6
Display
The lock waits for the
selecon of the me span
(connuous red ight).
Selecon of me spans Automac closing
Keys
0
Display
Switches o
Keys
1
Display
aer 10 seconds
Keys
2
Display
aer 30 seconds
Keys
3
Display
aer 1 minute
Keys
4
Display
aer 5 minutes
Keys
5
Display
aer 15 minutes
Keys
6
Display
aer 1 hour
Keys
7
Display
aer 6 hours
Keys
8
Display
aer 12 hours
Keys
9
Display
aer 24 hours