System Description
BDA M410 TA03 / 2019-09 (GB)
18
AUTOMATIC LOCKING IN FIXED CODE MODE
The lock must be in open posion. There must be no baery warning. This feature can only be acvated in Fixed
Code mode. If you have already changed the default master code, enter your valid master code here. In order to
conrm the master code, press the keys
x
+
simultaneously.
Select the me span aer which the lock is to close automacally.
Note that there may be slight variaons in the me span. A second-exact measurement is not possible. When swit-
ching to the Free Code mode, this funcon is automacally deacvated.
Enter of master code (example: factory sengs)
Keys
9
0
8
0
7
0
5
5
5
5
x
+
Display
The lock is in conguraon
mode (connuous green
light).
simultaneously
Keys
6
Display
The lock waits for the
selecon of the me span
(connuous red ight).
Selecon of me spans Automac closing
Keys
0
Display
Switches o
Keys
1
Display
aer 10 seconds
Keys
2
Display
aer 30 seconds
Keys
3
Display
aer 1 minute
Keys
4
Display
aer 5 minutes
Keys
5
Display
aer 15 minutes
Keys
6
Display
aer 1 hour
Keys
7
Display
aer 6 hours
Keys
8
Display
aer 12 hours
Keys
9
Display
aer 24 hours