Exterior 400™ range user manual
Dimensions All dimensions are in millimeters ©2010 Martin Professional A/S. Information subject to change without notice. Martin Professional A/S and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual.
Safety Information WARNING! Read the safety precautions in this section before installing, powering, operating or servicing this product. The following symbols are used to identify important safety information on the product and in this manual: WARNING! Safety hazard. Risk of severe injury or death. WARNING! WARNING! Hazardous LED light voltage. Risk of emission. Risk lethal or severe Group 3 electric shock. according to IEC 62471. WARNING! Fire hazard. WARNING! Refer to user manual.
PROTECTION FROM BURNS AND FIRE • Do not operate the fixture if the ambient temperature (Ta) exceeds 45° C (113° F). • The exterior of the fixture becomes hot, up to 90° C (194° F) during normal operation. Ensure that accidental physical contact with a hot fixture is impossible. • Allow the fixture to cool for 20 minutes before servicing. • Do not illuminate surfaces less than 0.1 m (4 in.) from the front surface of the fixture. • Keep flammable materials well away from the fixture.
Contents Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Unpacking . . . . . . . . . . . .
Introduction Thank you for selecting a product from the Exterior 400™ range of compact LED-based floodlights from Martin Professional™.
Physical installation Warning! Read "Safety Information" on page 3 before installing the Exterior 400 range. Warning! The safety and suitability of lifting equipment, installation location, anchoring method, mounting hardware and electrical installation is the responsibility of the installer. All local safety regulations and legal requirements must be observed when installing and connecting the Exterior 400 range. Installation must be carried out by qualified professionals only.
If additional bolts are required to mount the fixture safely, install bolts through holes B and slots C. 200 Ø53 C 82 C 90° A B B 60 9 Ø13 Figure 1: Mounting yoke attachment points Tilt adjustment Tilt adjustment can be carried out with the fixture powered on. To adjust the tilt: 1. Put on heat-resistant gloves if the fixture is or has recently been powered on. 2. See Figure 2. Loosen, but do not remove, the tilt-lock screws. Tilt the fixture to the desired angle and retighten the screws.
Power and DMX data cable layout Figure 3 gives an overview of a suitable cable layout. The dotted lines represent AC power circuits. The solid lines represent the data link. DMX Universe #2 Fixture Fixture DMX Power Universe #2 230V AC OPTOSPLITTER Fixture OPTOSPLITTER 50 Hz ACPower power 230V AC 50 Hz Fixture Fixture Fixture DMX Universe #1 DMX Universe #1 Power 230V AC AC power 50 Hz Power Fixture Fixture OPTOSPLITTER Max. 32 luminaires or 500m. before opto-splitter is required.
AC power DANGER! Read “Safety Information” on page 3 before attempting to install an Exterior 400 range fixture. Lock out power to the entire installation before working on cables and connections or removing any cover. Electrical installation must be carried out by qualified professionals only. For protection from dangerous electric shock, the fixture must be grounded (earthed).
3. Check that all installation work is completed and carry out appropriate tests and safety checks before applying power. Replacing the power cable If you replace the supplied power cable, the new cable must be listed, adequately dimensioned for the current requirements and suitable for the installation environment, particularly with regard to water, pollution, thermal and UV resistance. Use Hypalon or neoprene rubber-jacket cable rated to 90° C (194° F) minimum. The conductor size must be 1.
- If using two phases of a three-phase system to obtain 200 - 240 V between two phases, connect one phase to terminal L and the other phase to terminal L2. Do not connect anything to terminal N. - If using a single-phase three-wire earthed mid-point system (used in certain regions of the USA) to obtain 200 240 V between two live conductors, connect one live wire to terminal L and the other live wire to terminal L2. Do not connect anything to terminal N. 7.
Control data link Exterior 400 range fixtures must be connected via a control data link for DMX controller or synchronized (master/slave) operation.The following considerations must be taken into account when planning the data link: • RS-485 data cable designed for exterior use is required for outdoor installations. RS-485 cable has low capacitance and a characteristic impedance of 85 to 150 Ohms. It is electrically shielded and has at least 1 twisted pair of conductors.
RJ-45 connection RJ-45 connectors are suitable if CAT 5 cable is used for the data link. RJ-45 cable connector pins are numbered from the left looking at the face of the connector with the locking clip on top (see Figure 8).
Fixture setup Setting up a fixture with a PC and MUM The Martin MUM (Multi-Utility Manager) application allows you to program and configure Martin Exterior 400 range fixtures from a laptop PC and features an intuitive GUI (graphic user interface). Using MUM, you can connect to and set up one fixture at a time. Refer to the MUM user manual for instructions on installing and starting the MUM application.
Configuring a fixture with MUM Setting the clock Exterior 400 range fixtures have a battery-operated 24-hour clock that is used to start and stop stand-alone operation. To set the clock: 1. Click on the Fixture Info button in MUM: Figure 11: Fixture info window 2. Using the Fixture real-time clock spin buttons, set the fixture to the current time (expressed in the 24-hour clock in hours and minutes) and date. The time will be updated in the fixture in real time.
DMX Address To set the DMX address using MUM, click on the Fixture settings button and use the DMX Address spin buttons to set the fixture’s DMX address. The DMX address will be updated in the fixture in real time.
Operation Exterior 400 range fixtures can be operated using a DMX controller or programmed to run a stand-alone light show without DMX control. Ambient temperatures The Exterior 400 range can be operated at ambient temperatures from -30° C (-22° F) to 45° C (113° F). At temperatures below 0° C (32° F), leave the fixture permanently powered on, even if LEDs are dimmed to zero because light output is not required.
Stand-alone operation In stand-alone operation, the fixture executes color changes at set intervals and speeds, at pre-defined periods during the day, and/or when the light level falls below a defined level. The term stand-alone means that the Exterior 400 range is not connected to a control device, but is pre-programmed with a sequence of up to 20 scenes that play continuously in a loop.
Setting a light-level trigger To set a light-level trigger: 1. Set Light level sensor trigger to On. 2. Set the light level that triggers stand-alone operation using the Trigger level spin button, or press Capture current sensor value to set the current ambient light level to trigger stand-alone operation.
Scene management Once you have specified values for the effects and fade and wait times for the scene, you can store and manage scenes using the commands available at the bottom of the Stand-alone program window: Store scene Save settings in the current scene. Add scene Save settings in a new scene at the end of the current sequence of scenes. Insert scene Save settings in a new scene before the current scene.
It is important to note that the only commands transmitted by the master are scene change and show start commands. No data about the appearance of the scene is transmitted between fixtures. If you are programming a group of fixtures to perform the same scenes with synchronized master/slave triggering, we recommend that you: 1. Use MUM to program a show on one slave fixture 2. Download and save this fixture’s program and settings to your PC using MUM’s Files menu (see Figure 16), and then 3.
Note that in the following example, the scenes in the slave run out of their programmed sequence because scenes 0 and 2 on the slave are longer than the corresponding scenes on the master. M=master, S=slave F=fade, W=wait Time > Programmed M0 Master F W S0 Slave F W M1 F Result Master M1 F Slave M0 F W S0 F W M2 F W S1 F W S2 F W Operation W W M2 F S2 F W W M0 F W .. .. M1 F S1 F W W .. ..
Service and maintenance DANGER! Read “Safety Information” on page 3 before carrying out service or maintenance work on the Exterior 400 range. Lock out power to the entire distribution system before servicing or opening any cover. Important! The Exterior 400 range requires regular service and maintenance to maintain reliable operation and protect the investment it represents. Excessive dirt and particle buildup degrades performance, causes overheating and will damage the fixture.
Installing and removing a diffuser filter Important! Install diffuser filter sheets with the matt, textured surface against the front glass and shiny, untextured surface facing in towards the LEDs. Exterior 400 range fixtures are supplied with no diffuser filter installed and narrow, medium and wide diffuser filters packed separately with each product. Diffuser filters soften the output from the LEDs and alter the beam angle. See Figure 18. Diffuser filters are marked with notches to identify them.
Fuse replacement DANGER! Lock out power to the entire distribution system before servicing or opening any cover. Replace fuses with ones of the same type and rating only. Primary fuse Exterior 400 range fixtures are protected by a 2.5 amp slow-blow primary fuse located on the power PCB. If a fixture is completely dead, the primary fuse may have blown. To replace the primary fuse: 1. Isolate the fixture from power and allow to cool for 20 minutes. 2. Open the rear cover (see Figure 4 on page 11). 3.
• The Martin Uploader application, version 5.0 or later, downloadable free of charge from the Support area of the Martin website. • The fixture’s main CPU software update file, downloadable free of charge from the Support area of the Martin website (this file can be downloaded automatically from within the Martin Uploader application) • A Martin Universal USB-DMX Interface or similar PC/fixture hardware interface and a Windows PC (if you have a Martin MP-2 Uploader device, it can also be used).
Status indicators Two LEDs on the rear cover give information about fixture status. LED 1 (Fixture status) • Flashes red if an error occurs that requires service intervention. • Lights steady green when the fixture is ready for operation. • Lights steady yellow during a software upload. • Flashes yellow while the fixture is resetting. LED 2 (DMX status) • • • • • 28 Lights steady red if the fixture receives data it cannot recognize.
DMX protocols Exterior 400, Exterior 410 RGB Mode (calibrated) Start code = 0 Channel 1 2 3 Value Percent Function 0 - 255 0 - 100% Red Intensity 0 →100% 0 - 255 0 - 100% Green Intensity 0 →100% 0 - 255 0 - 100% Blue Intensity 0 →100% RGBW Mode (raw) Start code = 0 Channel Value Percent Function 0 - 255 0 - 100% Red Intensity 0 →100% 0 - 255 0 - 100% Green Intensity 0 →100% 0 - 255 0 - 100% Blue Intensity 0 →100% 0 - 255 0 - 100% White Intensity 0 →100% Channel Value Percent
HSIC Mode (calibrated) Start code = 0 Channel Value Percent Function 1 0 - 255 0 - 100 Hue Red → Orange → Yellow → Green → Cyan → Blue → Indigo → Violet → Magenta → Red 0 - 255 0 - 100 0 - 255 0 - 100% 0 - 255 0 - 100 2 3 4 Saturation Zero (white) → Full saturation Intensity Intensity 0 →100% Color Temperature Control Exterior 420 Color temperature control Start code = 0 Channel 1 2 Value Percent Function 0 - 255 0 - 100 Color temperature Warm → cold 0 - 255 0 - 100% Intensity Inten
Troubleshooting Problem Fixture is completely dead. One or more fixtures responds incorrectly to control or does not respond at all. LEDs cut out intermittently. Probable cause(s) Remedy No power to fixture. Check power and connections. Primary fuse blown. Isolate fixture from power. Check fuse and replace. Fault on DMX link. Inspect connections and cables. Correct poor connections. Repair or replace damaged cables. Incorrect fixture addressing. Check fixture is set to correct DMX mode.
Specifications Physical Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 mm (6.7 in.) including cable gland Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .307 mm (12.1 in.) Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .401 mm (15.8 in.) Weight . . . . . . . . . . . . . . . . . .
Connections Power cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP68 cable gland Power connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8 m (5.9 ft.) cable tail Data cable entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP68 cable gland Data connection. . . . . . . . . . . . . . . . . . . . . . . .
Exterior 410™ Exterior 410 EU model (aluminum) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90545053 Exterior 410 US model (aluminum) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90545151 Exterior 410 EU model (black) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90545061 Exterior 410 US model (black) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
www.martin.