Routine maintenance
The MAC 700 Wash requires routine cleaning. The schedule depends heavily on the operating
environment. It is essential to follow the cleaning guidelines given later in this section.
Refer any service operation that is not described here to a qualified Martin technician.
Important! Excessive dust, smoke fluid, and particulate buildup degrades performance, causes
overheating and will damage the fixture. Damage caused by inadequate maintenance is not
covered by the warranty.
Warning! Disconnect the fixture from power and allow to cool for at least 45 minutes before
removing any cover.
Tilt lock
Important! Release the tilt lock before operating the fixture.
The tilt position of the head can be locked for transportation and
service with the tilt lock. To lock or unlock the head, pull the lock
out and turn it one-quarter turn in either direction.
Disassembly
To access the effects module
1. Disconnect the fixture from power and allow it to cool for 45 minutes.
2. Turn the four retaining screws in the top and bottom head covers one quarter-turn counter-clockwise to
release the covers.
3. Remove the front lens by twisting one quarter-turn counter-clockwise.
4. Position the head top side up so that you have access through the top. Holding the zoom lens by its
base, slide it out it to its limit at the front of the fixture.
Figure 9: Tilt lock
Figure 10: Releasing top and bottom covers and removing front lens