User manual

Display messages 31
Display messages
Message Appears when... What to do
 (Reset)
... the fixture is indexing effects at startup. Wait for reset to complete.
 (Serial reset) ... the fixture has received a reset command.
Wait for reset to complete. Note that
you can set
 to 
to prevent accidental DMX reset
commands.

...the lamp access cover is not fully closed.
Check that lamp access cover is locked
in place.
 (Lamp error)
... the lamp does not ignite within 30 seconds
of receiving the ‘Lamp ON’ command. Likely
reasons are a missing or defective lamp, or
insufficient AC voltage.
Check lamp. Check that local voltage is
within specification.
 (Light sensor 1 error)
...there is a malfunction in the light sensor 1
circuit.
Contact Martin service for assistance.
 (Memory error) ...the EEPROM memory cannot be read. Contact Martin service for assistance.
 last character in display rotates
(Upload error)
...a software upload is unsuccessful. Reload software.

... there is no communication between the
control panel and motherboard (it is normal for
this readout to appear briefly when the fixture
is powered on).
Check fuses and replace accordingly.
Check that cable between control panel
and motherboard is connected
properly. Reinstall software.
 (Short error)
... the fixture detects the lamp is ON but no
‘Lamp ON’ command has been received. This
can occur if the lamp relay is stuck or if the
lamp-power feedback circuit fails. The fixture
may be operated but remote lamp on/off may
be affected.
Contact Martin service personnel for
assistance.
 (Base temperature sensor error)
 (Lamp temperature sensor error)
 (Switchmode/ballast side
temperature sensor error)
...there is a malfunction in the temperature
sensing circuit.
Contact Martin service personnel for
assistance.
 (Lamp temperature cut-out)
... the lamp temperature is too high and
thermal protection circuits cut power to the
lamp.
Allow fixture to cool.
Ensure nothing is obstructing airflow
around fixture.
Clean air vents, air filters and fans.
Reduce ambient temperature.
Contact Martin service personnel if
problem continues.
 (Feedback error pan)
 (Feedback error tilt)
 (Feedback error pan/tilt)
...there is a malfunction in the optical pan/tilt
monitoring circuit (e.g. sensor defective). After
a time-out, the effect in question stops in a
random position.
Reset fixture. Contact Martin service
personnel if problem continues.
 (Pan time-out)
 (Tilt time-out)
 (Zoom time-out)
...there is a malfunction in the electric indexing
circuit for pan, tilt, focus or zoom. The fixture
will, after the time-out, establish a mechanical
stop, and continue to work normally.
Reset fixture. Contact Martin service
personnel if problem continues.
 (Color wheel time-out))
...there is a color wheel indexing or indexing
sensor error (e.g. color wheel will not index
correctly, sensor circuit defective or magnet
missing). After the time-out, the effect in
question stops in a random position.
Reset fixture. Contact Martin service
personnel if problem continues.
(Cyan time-out)
(Magenta time-out))
(Yellow time-out)
(CTC time-out)
(Beamshaper time-out)
(Beamshaper rotation time-out)
...there is an effect position or position sensor
circuit error for one of the CMYC flags or the
beamshaper.
Reset fixture. Contact Martin service
personnel if problem continues.

...there is a driver error. Contact Martin service for assistance.

...there is an display programming error. Contact Martin service for assistance.
Table 6: Display messages