Specifications

Drawn by
: GS 28/03/2006
Drawing No. 2000-1A
1
5
4
2
3
VIEWED FROM THE SOLDER SIDE
OF THE DIN PLUG
5, 0 - 10v INPUT, NEEDS 1.5v TO HEAT AND
2v -10v PUMP SPEED WHEN MACHINES READY
PIN OUT DESCRIPTION
1, GND WHEN MACHINES UP TO TEMPERATURE
4, GND WHEN MACHINES HEATING
2, GND
3 +16v OUTPUT
MAGNUM 800 REMOTE CONTROL DIN PLUG PIN OUTS
1 - YELLOW (READY).
4 - WHITE (HEAT).
5 - BLUE (0 - 10v)
3 - RED (+16v).
2 - BLACK (GND).
Magnum 800 Remote Plug Pin