User Manual
RUSH Wizard User Manual 17
4 - DMX XLR input/output sockets
5-pin XLR sockets are provided for DMX input and output (throughput).
5 – AC mains power input
A blue Neutrik PowerCon socket is provided to connect the fixture to mains
power.
6 - Mains power throughput
The white Neutrik PowerCon socket can be used to supply power to other
fixtures only if safety limits (see ‘Safety information’ on page 4) are respected.
7 - Microphone
Built-in microphone for sound-activated scene changes (music trig) in show
mode.
8 - Fuse
The T 6.3A fixture fuse F1 is located in a fuseholder next to the AC mains
power connectors.
9 - Safety cable attachment point
Loop a secondary attachment such as an approved safety cable that is rated
for the weight of the fixture through this attachment.