AC power
AC
POWER
2
The MX-4 power supply has 5 voltage and 2 frequency settings. The factory default
setting is shown on the serial number label.
Warning! For protection from fire and electric shock, the fixture must be
grounded (earthed). The power supply shall have overload and
ground-fault protection.
Warning! Verify that the feed cables are undamaged and rated for the
current requirements of all connected devices before use.
Important! Check the power supply setting before applying power.
Important! The mirror assembly is secured for transport with a plastic tie.
Cut and remove the tie before applying power.
Important! Do not connect the fixture to a dimmer system.
To install a plug on the mains lead
The mains lead must be fitted with a grounding-type cord cap that fits your
power distribution system. Consult a qualified electrician if you have any
doubts about proper installation.
Following the cord cap manufacturers instructions, connect the yellow and
green wire to ground (earth), the brown wire to live, and the blue wire to neutral.
The table below shows some pin identification schemes.
Wire Pin Marking Screw color
brown live “L” yellow or brass
blue neutral “N” silver
yellow/green ground green
Table 1: Cord cap wiring