User manual

PAL 1200, PAL 1200 E, PAL 1200 FX User Manual 7
Removing the transport fixture
In order to protect the pan/tilt assembly from becoming damaged during shipment it has been secured with black plastic straps.
Cut and remove these plastic straps.
Fitting the mirror
1.
Release the two thumbscrews on the tilt motor.
2.
Place the mirror on the tilt motor.
3.
Tighten the two thumbscrews.
4.
Carefully remove the surface protection foil from the mirror.
Installing the lamp
WARNING!
Make sure that the fixture is isolated from the mains supply.
The PAL may be used with either the Osram HSR 1200 or the Philips MSR 1200 lamp.
1.
Remove the three screws that secure the access plate of the lamp socket assembly at the rear of the PAL
and with-
draw the lamp socket assembly.
2.
Hold the lamp by the ceramic parts, avoiding touching the glass part with your fingers, and carefully insert it
into the lamp socket. If you accidentally touch the glass part with your fingers you must clean it thoroughly
with the cleaning cloth supplied with the lamp. You can also use a clean lint free cloth wetted with alcohol.
3.
Replace the lamp socket assembly, ensuring that the lamp locates properly into the aluminum reflector, and
tighten the Philips screws.
NOTE:
The lamp position is adjusted at the factory, however, re-adjustment may be necessary to optimize the light output
and the color uniformity with the CMY (Cyan, Magenta, Yellow) system. Please refer to “Optimizing the lamp alignment” on
page 21.
Fitting the mains plug
The PAL is delivered from the factory without a plug on the mains cable. You will have to fit a plug that conforms to your local
mains outlet. The double-insulated mains cable contains three wires.
1.
Connect the BROWN wire to the LIVE pin.
2.
Connect the BLUE wire to the NEUTRAL pin.
3.
Connect the YELLOW/GREEN wire to the EARTH pin.
Checking voltage and frequency settings
It is vital that both voltage and frequency settings of the PAL match the local power supply. If this is not the case, you will have
to rewire the fixture as described under “Voltage and frequency settings” on page 22. The factory setting of voltage and fre-
quency is printed on the serial number label at the back of the fixture.
Rigging the PAL
You can now rig the fixture by means of its mounting bracket. The PAL has a graduated scale on each side of the body which
allows you to align it with other fixtures. The mounting bracket allows you to tilt the fixture from 70° up to 60° down. Use the
lever handles on the sides to lock the fixture into the desired angle.