User manual

AC power 15
5. Insert each of the wire ends into
the appropriate terminal (see
illustration on right and Table 1
above) and fasten using a small
flathead screwdriver.
6. Push and insert the chuck into the
housing (note that there is a
raised key on the chuck to ensure
that it is oriented correctly).
7. Fasten the bushing using a
wrench to a torque of 2.5 Nm (1.8 lb.-ft).
Illustrations in this section used by kind permission of Neutrik AG.
Relaying power to other devices
Warning! The current load of all devices connected to AC mains
power in one interconnected chain via the RDM 5.5 Splitter’s power
throughput outlet must not exceed 19.6 amps.
Devices can be linked in a chain, power throughput to power input, so that
they all draw AC mains power via the RDM 5.5 Splitter’s Neutrik
PowerCon power throughput socket, but certain points must be
respected:
Power cable that meets the requirements specified on page 5 of this
manual must be used to connect the RDM 5.5 Splitter to AC mains
power and to connect all the devices in the chain to each other.
A light-grey Neutrik PowerCon NAC3FCB cable-mount connector must
be used to draw AC mains power from the RDM 5.5 Splitter’s power
throughput socket and a blue Neutrik PowerCon NAC3FCA cable-
mount connector must be used to supply power at the RDM 5.5
Splitter’s power input socket.
No matter what the AC mains power voltage is, the current draw of all
the devices that draw AC mains power in one interconnected chain
from the power throughput socket of an RDM 5.5 Splitter that is
connected directly to AC power must not exceed 19.6 amps total.
Terminals