© 1995-1996 Martin Professional A/S Part# 510061 Roboscan Pro 1220 operator’s manual
© 1995-1996 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. Printed in Denmark. Revision #961029-PS. P/N 510061.
section 1 INTRODUCTION The Roboscan Pro 1220 features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 section 2 INSTALLING THE PRO 1220 Installing the Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Fitting the Mains Plug. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
section 6 HARDWARE SETTINGS AND ADJUSTMENTS Removing and Replacing Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltage and Frequency Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lamp Replacement and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjusting the Pan/Tilt Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjusting the Pan/Tilt Dampers. . . . . . . . . . . . . . . . . . . . . . .
section 1 INTRODUCTION Congratulations on your choice of the Roboscan Pro 1220, designed and manufactured by Martin Professional. The Roboscan Pro 1220 is a high performance, intelligent lighting projector meeting the demands of tomorrow's lighting designers. The rugged construction combined with the use of high quality components ensures that your Roboscan Pro 1220 will perform reliably for many years to come. The Roboscan Pro 1220 features • • LIGHT SOURCE 1200 Watt HMI or MSR lamp depending on model.
• Fixed and rotating gobos can be combined. • • DIMMER / SHUTTER High-speed shutter (2 to 16 Hz) for instant black-out and fast strobe. 0 to 100% smooth dimming with micro-stepping resolution. • FOCUS Motorized focus with precision coated optics. • IRIS Motorized iris for different beam diameters. • • • EFFECT WHEEL (PRO 1220 CMYR / XR) 3 and 5 facet prism for multiplying images. Frost filter for soft-edged images. Hot Color Temperature Correction (Pro 1220 XR only).
About this Manual Device Version(s) Part# CPU A Section 2.0 219806 CPU B Section 2.0 219806 CPU Control Module 3.3 , 3.4 219810 EPROM A Section 2.6 , 2.7 , 2.8 219025 EPROM B Section 2.6 , 2.7 219026 CPU A Section 2.0 219806 CPU Control Module 3.3 , 3.4 219812 EPROM A Section 1.4 , 1.5 , 1.6 219030 CPU A Section 2.0 219806 CPU B Section 2.0 219806 CPU Control Module 1.1 219814 EPROM A Section 1.0 219027 EPROM B Section 1.
section 2 INSTALLING THE PRO 1220 The Roboscan Pro 1220 is delivered fully prepared from the factory so only a few basic procedures are necessary, and you will be ready to operate your new lighting equipment. Your Roboscan Pro 1220 package comes complete with the following items: • • • • • Roboscan Pro 1220 CMYR / Pro 1220 XR / Pro 1220 RPR. Mounting bracket including fittings. 5 metres XLR-XLR cable for control. User's manual. 15 metres power multi-cable (Pro 1220 Studio Version only).
carefully insert it into the lamp socket. 6. Again, without touching the glass envelope with your fingers, turn the lamp around its centreaxis until the small nipple on the bulb is straight up and thus facing the chassis plate when the lamp module is replaced in the fixture. Then tighten the finger nuts on the lamp, thus securing it to the holder. 7. Carefully clean the lamp using the cleaning cloth provided with the lamp. 8. Replace the lamp module and tighten the two finger screws. 9.
Fitting the Mains Plug The Roboscan Pro 1220 is delivered from the factory without a plug on the mains cable. You will have to fit a suitable plug (one that fits your local mains outlet) before you can connect the fixture to the mains. The double insulated mains cable contains three wires. 1. Connect the BROWN wire to the LIVE pin. 2. Connect the BLUE wire to the NEUTRAL pin. 3. Connect the YELLOW/GREEN wire to the EARTH pin.
Fitting the Mounting Bracket The mounting bracket is already fitted onto the Pro 1220, however, you will have to secure it before rigging the fixture. 1. Locate the four studs that come out through the bracket on the sides of the Pro 1220. 2. Secure the bracket by first fitting the four metal washers and then the four lever handles that came with the Pro 1220.
section 3 OPERATING VIA A LIGHTING CONTROLLER All effects in the Roboscan Pro 1220 are fully DMX 512 and Martin RS-485 implemented, i.e you can use any DMX board or the Martin 3032 controller to operate it. All control data are transmitted from the controller’s output, via XLR data link cables, to the data input on the Roboscan Pro 1220 (that is the 3 pin XLR male on the front).
5 pin XLR male: Pin 1 = GND (screen) Pin 2 = signal (-) Pin 3 = signal (+) Pin 4 = N/C Pin 5 = N/C 3 pin XLR female: Pin 1 = GND (screen) Pin 2 = signal (+) Pin 3 = signal (-) The above figure shows the cable to connect from 5-pin DMX output to 3-pin input on Martin fixture (P/N 309162).
The control module on the front end of the Pro 1220 allows you to set the DMX protocol and assign the fixture address, which is defined as the first channel from which the Pro 1220 will respond to the controller. If you select a protocol that requires 15 channels and you set the address to channel 10, the Pro 1220 will be using channel 10 to 24 for control.
section 4 REMOTELY CONTROLLABLE FUNCTIONS This section briefly describes the various Pro 1220 functions that can be remotely controlled via the serial data input on the fixture. LAMP The Pro 1220 uses a 1200 Watt discharge lamp - the HMI 1200 from Osram or the MSR 1200 from Philips. Both lamps provide a high light output throughout their rated lamp lives of 750 hours. The color temperature is 5600 K for the MSR and 6000 K for the HMI.
COLOR WHEELS (PRO 1220 CMYR AND RPR ONLY) The Pro 1220 CMYR has two separate and overlapping color wheels each with 10 color positions 9 of these with dichroic colors and the last one open. Both 'hot' and 'cold' CTCs (Color Temperature Correctors) are available on color wheel 2 and so is a special filter that only allows U.V. light to pass. The wheel can be positioned between two adjacent colors, thus splitting the beam into these colors.
DIMMER / SHUTTER High resolution, 0 to 100% smooth dimming is provided by the combined dimmer/shutter system. Use high speed dimming if you wish to open or close the dimmer instantly. It is also possible to strobe at different frequencies (1.6 to 15.6 Hz). FOCUS The Pro 1220 uses a motorized focus system which allows remote focusing at any time. IRIS The beam angle can be reduced from 18.5° down to 2.5° using the iris.
section 5 THE PRO 1220 CONTROL MODULE The control module on the front end of the Pro 1220 offers several features. You can easily set the fixture address, read the number of lamp hours, enable special soft-features etc. The main-menu is accessed by pressing the menu key - press [enter]. The display will then show one option at a time.
PSEt - Protocol Setup After switching on a Pro 1220, it will automatically detect whether Martin or DMX signals are received and use the appropriate protocol type. The PSEt (protocol set-up) function allows you to switch protocol and/or protocol type afterwards. Use the arrow keys to select the desired protocol and press [enter] to confirm or [menu] to cancel. Either way you will return to the main menu.
Use the arrow keys to toggle between on and off. Select 'on', by pressing [enter], if wish the protocol auto-detect function to be enabled after switching on the fixture, and 'off' if you wish to disable the feature. PAn This function allows you to invert the pan movement (DMX Protocol only). Use the arrow keys to toggle between Inu for inverted pan and nInu for non inverted and press [enter] to confirm or [menu] to cancel. Either way you will return to the SPEC-menu.
SP 1 to SP16 Up to 16 special service and adjustment sequences are available. These are mainly used for servicing purposes. After selecting a sequence, use the arrow keys to step through the sequence. Press [menu] twice to return to the SPEC-menu. Please consult appendix b for table of the sequences Po H - Total Power-On Time (Fixture) This option allows you to read the total number of hours that the Pro 1220 fixture has been powered on.
ErrA The 'A-Module Error' indicates that there is no communication between the serial data receiver module and the A-Section electronics-module. Errb (Pro 1220 CMYR only) The 'B-Module Error' indicates that there is no communication between the serial data receiver module and the B-Section electronics-module. ShEr 'Short Error' appears if the Pro 1220 "detects" that the lamp is on but no 'Lamp On' command has been sent.
section 6 H A R D WA R E S ET T IN GS A ND A D J U ST ME N T S The Roboscan Pro 1220 comes fully prepared from the factory, however, lamp adjustment and some pre-setting may be necessary before you can operate the fixture properly. You may also need to readjust some of the mechanical parts after extensive use. The procedures for doing this are carefully described in this chapter. IMPORTANT! We recommend that you read the following information carefully before attempting to make any alterations whatsoever.
REPLACING A MODULE To replace the module simply reverse the steps above being careful when you replace the module to ensure that it is straight and locates properly: There are two pins on the bottom of the module which have to locate into holes in the inner casing before you are able to re-tighten the finger screws. Voltage and Frequency Setting Five voltage and two frequency settings can be selected in any combination on the Pro 1220.
Correct Voltage Setting Local Mains Voltage Correct Voltage Setting Local Mains Voltage 100 V 95 - 110 V 210 V 200 - 220 V 120 V 110 - 130 V 230 V 230 - 240 V 250 V 240 - 260 V Lamp Replacement and Adjustment To reduce the risk of the lamp shattering it is strongly recommended that the lamp is replaced when the rated average life has been exceeded by 25%. Since the rated average life for both the MSR 1200 and HHI 1200 lamp is 750 hours, they should be replaced before 900 to 950 hours of use.
HMI 1200 LAMP 1. Locate the 3 adjustment screws on the back of the lamp module and turn all three of them as much counter clockwise as possible. 2. Turn only one of the two nearest screws clockwise until the centre axis of the HMI 1200 lamp is parallel to the reflector plate. 3. Switch on the Pro 1220 and wait until 'reset' has finished. 4. Using the controller, power on the lamp and open the dimmer. 5.
Adjusting the Pan/Tilt Stops Re-adjusting the mechanical stop on the Roboscan Pro 1220-mirror adaptor is required if the pan or tilt motor intermittently loses steps or leaves the mirror incorrectly positioned after a 'reset' is performed. This error can occur when the recoil of the mechanical reset bounces the mirror and bracket a whole pan or tilt motor step. These adjustments require that your are familiar with the service sequences provided by the control module on the front end of the Pro 1220.
5. Reset the Roboscan Pro 1220 a number of times to check the accuracy of the new reset position. 6. Again, select the service sequence named 'SP 6' and toggle between 'St 2' and 'St 3' whilst checking that adjustment screw (B1) does NOT touch the mechanical stop (B2) during these steps. If it does then adjust screw (B1) accordingly. TILT-MOTOR ADJUSTMENT 1. Select 'St 4' (step 4) so that the top mechanical-stop (C1) in the previous figure is positioned at the edge of the mirror bracket (C2). 2.
If the dampers are set to a position that is too tight you will find that it will affect the smoothness of the mirror movement at the lower movement speeds. Regenerating Malfunctioning Lamps Discharge lamps, like the HMI 1200 and MSR 1200, may refuse to strike if the mains voltage applied to the fixture is too low. Instead, the lamp will burn with a faint blue arc and after a period of time the lamp will become black on the inside. When this happens the lamp will refuse to start at normal voltage.
section 7 MAINTENANCE To ensure optimum and uninterrupted performance from the Pro 1220 it is important to keep it clean at all times. Dusty lenses will reduce the brightness and blocked fans may cause overheating, thus causing the thermostat to cut off the lamp intermittently. Thanks to the modular construction of the Pro 1220, maintenance can be done easily and does not require any special tools. Simply remove the module(s), that you wish to clean, as described in the previous section.
appendix a DMX PROTOCOL DMX Channel Offset Pro 1220 CMYR - mode 1 2 3 Pro 1220 XR - mode 1 2 3 4 Pro 1220 RPR - mode 1 2 3 0 0 0 NOTE! Only with LoFF = on NOTE! Only with LoFF = on NOTE! Only with LoFF = on 0 0 0 NOTE! Only with LoFF = oFF NOTE! Only with LoFF = oFF NOTE! Only with LoFF = oFF 1 1 1 2 © 1995-1996 Martin Professional A/S 4 - 2 4 DMX Value Effect 0 - 49 50 - 177 178 - 199 200 - 243 244 - 247 248 - 251 252 - 255 Strobe, Fan Speed, Reset, Lamp On/Off No Functio
DMX Channel Offset Pro 1220 CMYR - mode 1 2 3 - 3 32 4 Pro 1220 XR - mode 1 2 3 2 - 4 Pro 1220 RPR - mode 1 2 3 - 3 4 DMX Value Effect 010 20 30 40 50 60 70 80 90 - 97 98 - 105 106 - 113 114 - 121 122 - 129 130 - 137 138 - 145 146 - 153 154 - 161 Color 1 (Pro 1220 XR) White Flame Red Pink Cyan Blue Yellow Orange Dark Blue Magenta Primary Green Dark Lavender Primary Green Magenta Dark Blue Orange Yellow Cyan Blue Pink Flame Red 162 - 208 209 - 255 Continuous Color Scr
DMX Channel Offset Pro 1220 CMYR - mode 1 2 3 4 © 1995-1996 Martin Professional A/S 7 Pro 1220 XR - mode 1 2 3 4 3 Pro 1220 RPR - mode 1 2 3 4 4 8 4 5 NOTE! Orientation and continous rotation parameters are programmed on channel 9 NOTE! Orientation and continous rotation parameters are programmed on channel 5 NOTE! Orientation and continous rotation parameters are programmed on channel 6 9 5 6 NOTE! The Pro 1220 will re-index the gobo before moving the gobo to the programmed orienta
DMX Channel Offset Pro 1220 CMYR - mode 1 2 3 4 Pro 1220 XR - mode 1 2 12 3 Pro 1220 RPR - mode 4 1 2 - - 3 4 - 8 - 9 - NOTE! Orientation and continous rotation parameters are programmed on channel 10 - 10 - 13 14 - 13 13 14 - 13 9 10 - 9 9 10 - 9 11 12 - 11 11 12 - 11 - 14 - 14 - 10 - 10 - 12 - 12 - 15 - 15 - 11 - 11 - 13 - 13 - 34 - NOTE! The Pro 1220 will re-index the prism before moving the gobo to the programmed orientation.
DMX Channel Offset Pro 1220 CMYR - mode Pro 1220 XR - mode Pro 1220 RPR - mode 1 2 3 4 1 2 3 4 1 2 3 4 - - 15 17 - - 11 13 - - 13 15 - 16 18 - - 12 14 - - 14 16 Effect 0 1 - 251 252 - 255 Speed: Pan, Tilt Tracking Speed Fast Slow Blackout while moving 0 1 - 251 252 - 255 Speed: Dimmer, Cyan, Magenta, Yellow, Iris, Focus Tracking Speed Fast Slow Fast Speed 0 1 - 251 252 - 255 Speed: Color1, Color2, Gobo1, Prism Tracking Speed Fast -> Slow Blackout while moving 0 -
appendix b S P E C I A L S E Q U EN C E S Sequence SP 1 Scene Description RESET ALL LAMP/OPTO ADJUST (Lamp On) - PRO 1220 CMYR and RPR ONLY St 1 All White St 2 Color 1 Opto Adjust - Feedback on Color 2 St 3 Color 2 Opto Adjust - Feedback on Color 1 SP 2 LAMP/OPTO ADJUST (Lamp On) - PRO 1220 XR ONLY SP 2 St 1 All White St 2 Color 1 Opto Adjust - Feedback on Gobo 1 CMY/DIMMER ADJUST (Lamp On) - PRO 1220 CMYR ONLY St 1 All Open St 2 Magenta to adjust position - Requires adjustment tool St 3
Sequence Scene Description PAN/TILT ADJUST (Lamp On) St 1 Neutral St 2 Pan Right St 3 Pan Left St 4 Tilt Up St 5 Tilt Down St 6 Right Up St 7 Left Up SP 6 St 8 Left Down St 9 Right Down EFFECT WHEEL ADJUST (Lamp On) - PRO 1220 CMYR ONLY St 1 SP 7 Open St 2 3-Facet Prism St 3 Frost St 4 5-Facet Prism EFFECT WHEEL ADJUST (Lamp On) - PRO 1220 XR ONLY St 1 SP 7 Open St 2 CTC St 3 Frost St 4 3-Facet St 5 Open St 6 5-Facet IRIS ADJUST (Lamp On) SP 8 St 1 Iris Open St
Sequence Scene Description LOCATING ROTATING GOBO INDEX (Lamp On) St 1 Open Gobo Selected St 2 Selecting Gobo 1 and Indexing St 3 Selecting Gobo 2 and Indexing St 4 Selecting Gobo 3 and Indexing St 5 Selecting Gobo 4 and Indexing SP10 PAN/TILT DAMPER ADJUST - SLOW SPEED MOVEMENTS (Lamp On) St 1 SP11 Pan Left, Tilt Neutral St 2 Pan Right, Tilt Neutral St 3 Pan Neutral, Tilt Up St 4 Pan Neutral, Tilt Down PRISM ADJUST (Lamp On) - PRO 1220 RPR ONLY SP12 St 1 Open Position (first) St 2
appendix c T E C HN I C A L S P E C I F I C A T I O N S Roboscan Pro 1220 CMYR / XR / RPR 1107 mm (43.6") 316 mm (12.4") 462 mm (18.2") 285 mm (11.2") Weight CMYR/XR/RPR models Weight CMYRST/XRST/RPRST models 53 kg (117 lb) / 51 Kg (112 lb) 47 kg (103 lb) / 45 Kg (99 lb) Fuse 20 AT (6.