Operator`s manual

36 Roboscan Pro 1220 - operator’s manual
appendix b
SPECIAL SEQUENCES
Sequence Scene Description
SP 1 RESET ALL
SP 2
LAMP/OPTO ADJUST (Lamp On) - PRO 1220 CMYR and RPR ONLY
St 1 All White
St 2 Color 1 Opto Adjust - Feedback on Color 2
St 3 Color 2 Opto Adjust - Feedback on Color 1
SP 2
LAMP/OPTO ADJUST (Lamp On) - PRO 1220 XR ONLY
St 1 All White
St 2 Color 1 Opto Adjust - Feedback on Gobo 1
SP 3
CMY/DIMMER ADJUST (Lamp On) - PRO 1220 CMYR ONLY
St 1 All Open
St 2 Magenta to adjust position - Requires adjustment tool
St 3 Cyan to adjust position - Requires adjustment tool
St 4 Yellow to adjust position - Requires adjustment tool
St 5 Dimmer to adjust position - Requires adjustment tool
St 6 Magenta Close
St 7 Cyan Close
St 8 Yellow Close
St 9 Dimmer Close
SP 3
DIMMER ADJUST (Lamp On) - PRO 1220 XR and RPR ONLY
St 1 Dimmer Open
St 2 Dimmer to adjust position - Requires adjustment tool
St 3 Dimmer Close
SP 4
GOBO ADJUST (Lamp On)
St 1 All Open
St 2 Gobo 1, Last Gobo
St 3 Rotating Gobo, Last Gobo
SP 5
FOCUS ADJUST (Lamp On)
St 1 Focus Front Stop
St 2 Focus Back Stop