User Manual

12 RUSH MH 5 Profile User Manual
3. The fixture is supplied with an omega-type bracket to which a rigging
clamp can be attached. Bolt a rigging clamp securely to the bracket. The
bolt used must be M12, grade 8.8 steel minimum, and fastened with a
self-locking nut.
4. Fasten the omega bracket to the base of the fixture
using the bracket’s quarter-turn fasteners. Turn quarter-
turn fasteners a full 90° to lock them (see illustration on
right).
5. Working from a stable platform, hang the fixture on the truss and fasten
the rigging clamp onto the truss.
6. Secure the fixture with a safety cable as directed below.
7. Check that the head will not collide with other fixtures or objects.
Securing with a safety
cable
Secure the fixture with a
safety cable (or other
secondary attachment) that
is approved for the weight of
the fixture so that the safety
cable will hold the fixture if
the primary attachment fails.
See illustration on right.
Loop the safety cable
through the cutout in the
fixture’s baseplate (arrowed)
and around a secure
anchoring point.
Martin™ can supply suitable
safety cables and rigging
clamps (see ‘Accessories’
on page 43).