The fixture is set to Blackout by default.
To set fixture behavior if the DMX signal stops:
1. Select DMX STATE
and press ENTER to confirm.
2. Use the UP and DOWN buttons to select:
MASTER/SLAVE – fixture runs in Master/Slave mode as described
above. The first fixture on the link (master) automatically sends
synchronizing information to other connected fixtures (slaves).
BLACKOUT – fixture blacks out.
HOLD – fixture continues to obey the last command that was sent via
DMX.
3. Press ENTER to confirm (or press MENU to exit without making a change).
Pan/tilt inversion
The PAN INVERSE and TILT INVERSE menus can be used to reverse the
direction of pan and tilt. These settings are useful for symmetrical effects with
multiple fixtures, or when coordinating the movement of fixtures that are floor
mounted and rigged upside down.
To adjust the pan inversion settings:
1. Select PAN INVERSE and press ENTER. The present mode will blink on
the display.
2. Use the DOWN and UP buttons to select the YES (tilt inversion) or NO
(normal) mode.
3. Press ENTER to confirm your selection.
To adjust the tilt inversion settings:
1. Select TILT INVERSE and press ENTER to confirm. The present mode will
blink on the display.
2. Use the DOWN and UP buttons to select the YES (tilt inversion) or NO
(normal) mode.
3. Press ENTER to confirm your selection.
Backlight
To adjust the control panel display backlight settings:
1. Select BACK LIGHT menu and press ENTER. The present mode will blink
on the display.
2. Use the DOWN and UP buttons to select the ON (LED on) or OFF (LED
off) mode.