User Manual
RUSH Wizard User Manual 11
Physical installation
Read ‘Safety information’ on page 4 before installing the
fixture.
The fixture is designed for indoor use only and must be used in
a dry location with adequate ventilation. Ensure that none of the
fixture’s ventilation slots are blocked.
Fasten the fixture to a secure structure or surface. Do not stand
it on a surface or leave it where it can be moved or fall over. If
you install the fixture in a location where it may cause injury or
damage if it falls, secure it as directed in this user manual using
a securely anchored safety cable that will hold the fixture if the
primary fastening method fails.
Martin™ can supply safety cables and rigging clamps that are suitable for use
with the fixture (see ‘Accessories’ on page 46).
Fastening the fixture to a flat
surface
To mount the fixture on a wall or
other vertical surface:
1. Check that the surface can
support at least 10 times the
weight of all fixtures and
equipment to be installed on it.
2. Obtain two 8 mm diameter hex
bolts or screwbolts with max. 13
mm head size and install them
90 mm (3.5 in.) apart (center to
center), in the mounting surface.
3. Install an eyebolt securely in the mounting surface to use as an anchoring
point for the fixture’s safety cable.
4. Fold the fixture’s mounting bracket so that it lies flat against the back of
the fixture and lock it in position by tightening the clamping handles. Lift
the clamping handles away from the bracket slightly until they turn freely,
then turn them so that they lie flat against the fixture and will not get in the
way when you hang the fixture on the mounting surface. Alternatively, you