5. See illustration on right.
Press the lamp down
against the lamp springs
until you can pull the top of
the lamp towards the back
of the fixture and free the
lamp. Then lift the lamp out
of the fixture.
6. Put on clean lint-free cotton gloves. Press the new lamp down against the
lamp springs until you can clip the top of the lamp into position. Check
that the new lamp is held securely in the same position as the old lamp
and is roughly centered relative to the aperture in front of the lamp.
7. Taking care not to damage wires or spade connectors, install the two
spade connectors on the lamp terminals in their original positions. Check
that the spade connectors are correctly fitted onto the lamp terminals and
secure, and check that the lamp wiring is in its original position.
8. Check that all wiring is in perfect condition. If any wiring is damaged,
return the product to Martin™ for repairs.
9. Reinstall the fixture cover in its original position, fastening all 9 screws
securely.
10. Power the fixture on. Enter the LAMP ON HOURS control panel menu
and press ENTER to display the current lamp hours. Press ENTER again
and then scroll to RESET TIME. Press ENTER to reset the lamp hours
counter to zero, then press and hold MENU to exit.
11. Send the old lamp to a waste disposal center that can correctly deal with
used discharge lamps.