Housing .................................... High-impact flame-retardant thermoplastic
Protection rating .................................................................................. IP 20
Installation
Mounting points ................................................................ Mounting bracket
Location ........... Dry location only, must be fastened to surface or structure
Orientation ............................................................................................. Any
Minimum distance to combustible materials ........................ 100 mm (4 in.)
Minimum distance to illuminated surfaces ........................ 200 mm (7.9 in.)
Connections
AC power input/throughput............................................. Neutrik PowerCon
DMX data input/throughput ............................................. 5-pin locking XLR
Electrical
AC power ....................................................... 100-240 V nominal, 50/60 Hz
Fuse .................................................................................................. T 6.3 A
Power supply unit .............................. Auto-ranging electronic switch mode
Power consumption figures are typical, not maximum. Allow for +/-10%
variation
Typical power and current
110 V, 60 Hz .............................................................. 1.9 A, 200 W, PF0.99
230 V, 50 Hz ............................................................. 0.9 A, 196 W, PF 0.95
Thermal
Cooling ........................................................................................ Forced air
Maximum ambient temperature (T
a
max.) ............................ 40° C (104° F)
Minimum ambient temperature (T
a
min) .................................... 0°C (32° F)
Total heat dissipation* .............................................................. 685 BTU/hr.
*Calculated, +/- 10%
Approvals
EU safety .................. EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493
EU EMC............................................... EN 55015, EN 55032, EN 55103-2,
...................................... EN 61000-3-2, EN 61000-3-3, EN 61547
US safety ........................................................................................ UL 1573
US EMC...................................................................... FCC Part 15 Class A
Canadian safety .................... CSA C22.2 No. E598-2-17 (CSA E60598-1)
Canadian EMC ............................................................... ICES-003 Class A
Australia/NZ .......................................................................... C-TICK N4241