Owner's Manual

Installing the Software
IMPORTANT! PBK software and the unique calibration file required to operate your
microphone must be downloaded to run PBK.
1. Go to http://www.martinlogan.com/PBK/software
2. Enter the serial number located on your microphone (six digit number beginning with ‘5’).
3. Right-click on the downloaded .zip file and extract it to the desktop.
4. Open the extracted folder and double-click on ‘ml-pbk-v2.01.exe’ (version number may
differ). Software installation instructions will appear on your screen.
5. Once installation is complete, delete the downloaded file and extracted folder.
6. Go to the Start Menu and run PBK.
Positioning the Microphone
IMPORTANT! During the measurement process, the microphone must point toward
the ceiling and be positioned at ear level when you are seated.
1. Position microphone on or near the first position (see diagram above right). Remove
cushions from seating, if necessary, to attain correct height. To adjust the height of the
telescoping stand, loosen the large black clamp in the middle of the stand by rotating it
counter-clockwise; retighten once desired height has been achieved.
Five listening positions will be measured and this can be manually increased to up to
10 positions, although in most cases only five are needed. The first position must be at
or just in front of the central seating position. Positions 2 and 3 should be symmetric
to the left and right of the center line. The same applies to the remaining positions.
IMPORTANT: Even if your room has less than five seating positions, to ensure
optimal sound, measurements must be taken from five different listening positions.
Each position should be at least 2 feet (60 cm) apart.
Measuring
1. Using the two USB ports, connect microphone and subwoofer to your computer. The first
time you run PBK you will need to wait while Windows installs drivers for the microphone
and subwoofer and indicates ‘new hardware is ready to use’.
2. Set the microphone in the first position;
3. Before starting to measure, set the subwoofer’s Gain control to its center detent position;
set Cut-Off Frequency to Bypass; and set Phase control to ‘0’. After running PBK, these
controls can be adjusted as necessary as you complete the setup of your system. See the
Owners Manual that came with your system for more details.
4. Run the Perfect Bass Kit by selecting it from the Start Menu. The program will guide you
through the steps and at the conclusion, will automatically load the correction data into
your subwoofer. The entire measurement process takes about 5 minutes;
5. Once the PBK program is finished you can disconnect the PC from the microphone
and subwoofer;
6. If position of subwoofer or listening positions change you will have to re-measure.
Sample PBK Analysis/Correction / Échantillon d’analyse/correction du PBK
:
The Perfect Bass Kit (PBK) is for use with any MartinLogan
®
subwoofer with a PBK
Interface to correct the effects of room boundaries on sound quality. PBK uses proprietary
processing to compute the subwoofer’s in-room frequency response and then computes a
target frequency response for the subwoofer to yield optimal in-room sound. PBK can be used
with up to four MartinLogan subwoofers. The frequency response of each PBK microphone
is measured precisely and this data is used to create the microphone’s calibration file included
on the PBK software disk. The microphone can ONLY be used with the matching individual
calibration file.
The PBK Kit includes:
Microphone and microphone clip
Telescoping stand and base
Two USB cables: one for microphone, one for subwoofer
Steps to assemble stand and microphone:
1. Screw the telescoping stand into the base and tighten securely;
2. Position the clip vertically and screw onto the stand; tighten;
3. Connect the USB microphone cable to the microphone;
4. Slide the microphone into the clip and point microphone straight up (see section
‘Positioning the Microphone’ for more information.)
THE PROCEDURE
1
= 1
st
First Measuring Position
1
ère
première position de mesure
1
Subwoofer
Frequency (Hz)
20
50
110
105
100
95
90
85
80
100
200
500
1k
dB
Before starting the procedure, note the following:
PC requirements are Windows XP, Windows 7 or Vista; and two USB ports. If you
are running a newer operating system than mentioned see info about updating
the PBK files.
If you are using a laptop computer, check power settings and battery meter before starting
to ensure the procedure will not be interrupted.
Although systems vary, in general, if your home theater receiver/processor also has a Room
Correction system, PBK should be set up and running before setting up your system’s ‘EQ’,
especially if more than one PBK subwoofer will be in use.
IMPORTANT! Don’t stand too close to the microphone or make noise when sweep
tones are playing (it would be best to keep younger or talkative family members and
even pets out of hearing range). The program rejects continuous background noise
(i.e. fans) but will give an error message requiring re-measurement upon sudden noise.
Measured / Mesuré
Calculated / Calculé
Target Response / Réponse cible