Warning Alarms
The Sentry System™ monitor will let you know if your unit is not
funconing properly for the following reasons. Door ajar, high or
low temperature, and power failure. These alarms are explained
below.
Door Ajar Alarm
If the drawer has been le open for over ve (5) minutes, the
alarm will sound and the LED will ash green. This will stop as
soon as the drawer is closed, or can be reset by pressing the
“ON/OFF” buon.
High and Low Temperature
If your unit reaches temperatures outside normal operang
temperatures for your set point for more than one (1) hour, an
alarm will sound and the LED will ash red. This will warn you
that your contents have seen temperatures that may not be con-
ducive for long-term storage. This alarm can be reset by pressing
the “ON/OFF” buon.
Power Failure
If your unit experiences a power failure, the LED will ash amber
unl the alarm is reset by pressing the “ON/OFF” buon.
Reset Alarms
Press the “ON/OFF” buon for approximately one (1) second.
This will reset all audible and display alarms when the buon is
released.
Enable/Disable Sentry System™ Alarms
Press and hold the “SET” key for ve (5) seconds to enable or dis-
able the Sentry System™alarms. LED will display a steady green
when enabled or a steady amber when disabled.
Quick Reference Guide
The quick reference guide on page 8 and 9 can be removed from
this manual and retained near the appliance for quick access to
the Sentry System™ funcons.
Figure 6
LED