Owner manual

Sentry System™ “Basic” Funcon “Quick” Reference
Note: All keypad presses are conrmed with an audible tone when released.
Funcon Funcon Access Control Conrmaon / Comment
Turn Unit On & O
Pressing and holding the “On/O” key for ve seconds will turn the unit “ON” or
“O.
The display will be blank when the refrigeraon system is o. Lights will sll funcon, but will
me-out in 15 minutes aer each acvaon if drawer is le open, to prevent overheang.
Adjust and View Temperature
set-point
To adjust the temperature set-point, press the “SET” key and current set-point will
be displayed. Use the “WARMER” or “COLDER” keys to adjust set-point tempera-
ture.
“SET” will appear in temperature display when in set-point mode. “SET” mode will automa-
cally me-out in ten (10) seconds if no keypad acvity occurs, or you may exit “SET” mode
by pressing the “SET” key .a second me.
Display “Actual” Temperature
The display represents real me monitoring. Some temperature uctuaon around
the set-point will be noceable as the refrigeraon system cycles on and o to
maintain the desired temperature.
Temperature variaon in “compartment” air, above and below set-point, is a normal eect of
refrigeraon system cycling on and o. Stored items will not experience the full temperature
swing of the compartment air due to the dampening eect of their thermal mass.
Select °F or °C Display
Pressing the “°F/°C” key will toggle the display between Fahrenheit and Cengrade
temperature display.
i.e. 55°F = 13°C
Sabbath Mode
Press and hold the “SET” key while pressing the “°F/°C” key four (4) mes in seven
(7) seconds.
The display will ash “SA” seven (7) mes, then the unit will enter Sabbath Mode. The
display, audible alarms, LED, and lights will be disabled. Sabbath Mode will automacally
me-out in 72 hours., or can be exited by repeang the enabling process.
Sentry System™ alarms
No acon required. System monitoring is automacally enabled unless system has
been disabled (see below).
Sentry System™ LED displays a steady green when Sentry System™ is enabled.
Drawer Ajar Alarm
No acon required if Sentry System™ is enabled. Audible alarm will sound 3 mes every 30 seconds, the LED will ash green. Close drawer to
reset alarm.
High/Low Temp Alarm
No acon is required if Sentry System™is enabled. NOTE: This alarm may occur
when changing set-points and/or high usage, this is normal.
Alarm will sound 6-mes every minute and LED will ash red if product temperature excur-
sions occur for a duraon outside acceptable limits.
Power Failure Alarm
No acon required if Sentry System™is enabled. NOTE: Alarm will occur upon inial
installaon, since unit was run at the factory to verify quality, this is normal.
LED will ash amber whenever power is interrupted to unit. There is no audible signal. Press
ON/OFF buon to reset alarm.
Reset Alarms
Close drawer to reset “DOOR AJAR” alarm. Press the “ON/OFF” key to reset all
other alarms.
Note that although pressing the “ON/OFF” key resets the alarms, the alarm will resume if
the “alarm condion” sll exists.
Enable / Disable Sentry
System™alarms
Press and hold the “SET” key for ve (5) seconds to enable or disable the Sentry
System™ alarms.
LED displays a steady green when alarms are enabled. LED displays a steady amber when
they are disabled.
8