Owner manual
Sentry System™ “Basic” Funcon “Quick” Reference
Note: All keypad presses are conrmed with an audible tone when released.
Funcon Funcon Access Control Conrmaon / Comment
Turn Unit On & O
Pressing and holding the “On/O” key for ve seconds will turn the unit “ON” or
“O”.
The display will be blank when the refrigeraon system is o. Lights will sll funcon, but will
me-out in 15 minutes aer each acvaon if drawer is le open, to prevent overheang.
Adjust and View Temperature
set-point
To adjust the temperature set-point, press the “SET” key and current set-point will
be displayed. Use the “WARMER” or “COLDER” keys to adjust set-point tempera-
ture.
“SET” will appear in temperature display when in set-point mode. “SET” mode will automa-
cally me-out in ten (10) seconds if no keypad acvity occurs, or you may exit “SET” mode
by pressing the “SET” key .a second me.
Display “Actual” Temperature
The display represents real me monitoring. Some temperature uctuaon around
the set-point will be noceable as the refrigeraon system cycles on and o to
maintain the desired temperature.
Temperature variaon in “compartment” air, above and below set-point, is a normal eect of
refrigeraon system cycling on and o. Stored items will not experience the full temperature
swing of the compartment air due to the dampening eect of their thermal mass.
Select °F or °C Display
Pressing the “°F/°C” key will toggle the display between Fahrenheit and Cengrade
temperature display.
i.e. 55°F = 13°C
Sabbath Mode
Press and hold the “SET” key while pressing the “°F/°C” key four (4) mes in seven
(7) seconds.
The display will ash “SA” seven (7) mes, then the unit will enter Sabbath Mode. The
display, audible alarms, LED, and lights will be disabled. Sabbath Mode will automacally
me-out in 72 hours., or can be exited by repeang the enabling process.
Sentry System™ alarms
No acon required. System monitoring is automacally enabled unless system has
been disabled (see below).
Sentry System™ LED displays a steady green when Sentry System™ is enabled.
Drawer Ajar Alarm
No acon required if Sentry System™ is enabled. Audible alarm will sound 3 mes every 30 seconds, the LED will ash green. Close drawer to
reset alarm.
High/Low Temp Alarm
No acon is required if Sentry System™is enabled. NOTE: This alarm may occur
when changing set-points and/or high usage, this is normal.
Alarm will sound 6-mes every minute and LED will ash red if product temperature excur-
sions occur for a duraon outside acceptable limits.
Power Failure Alarm
No acon required if Sentry System™is enabled. NOTE: Alarm will occur upon inial
installaon, since unit was run at the factory to verify quality, this is normal.
LED will ash amber whenever power is interrupted to unit. There is no audible signal. Press
ON/OFF buon to reset alarm.
Reset Alarms
Close drawer to reset “DOOR AJAR” alarm. Press the “ON/OFF” key to reset all
other alarms.
Note that although pressing the “ON/OFF” key resets the alarms, the alarm will resume if
the “alarm condion” sll exists.
Enable / Disable Sentry
System™alarms
Press and hold the “SET” key for ve (5) seconds to enable or disable the Sentry
System™ alarms.
LED displays a steady green when alarms are enabled. LED displays a steady amber when
they are disabled.
8