USING YOUR ELECTRONIC CONTROL
Door Ajar
ALARM RESET
NOTE
If the control lock is active (illuminated lock icon) the control
will have to be unlocked before using the keypad to reset
an alarm condition. See page 12 (Control Lock) for instruc-
tions for unlocking the control.
Control lock:
The control panel can be locked to avoid unintentional
changes. To lock the control, press and hold the "Lock" key-
pad until the display reads "Loc" then immediately release
your nger from the keypad. The lock icon will ash 3-times
and then continuously illuminate. When the control panel is
locked, only the Lock keypad, System Status OK indicator
, and the Alarm indicator are active. To un-lock the control
panel, repeat this instruction until the display reads "nLc",
then immediately release your nger from the keypad.
The temperature sensors are monitored continuously. Any
OPEN or SHORTED circuit condition will initiate an
ERROR CODE as listed below:
Temperature Sensor Error Codes
Sensor Displayed Code Error Description Action to Take
Single Zone
Temperature Sensor
Failed temperature sensor in the single
zone compartment. Can lead to unwant-
ed wine storage temperatures.
Call service to have the tem-
perature sensor replaced.
Defrost Sensor
Failed defrost temperature sensor.
Causes unit to not defrost properly and
can create large frost build-up. Can lead
to water damage to the unit and sur-
rounding oor.
Unplug the power cord imme-
diately and call service to have
the defrost sensor replaced.
Single Zone Models:
Dual Zone Models:
Temperature Sensor Error Codes
Sensor Displayed Code Error Description Action to Take
Upper Zone
Temperature Sensor
Failed temperature sensor in the upper
zone compartment. Can lead to unwant-
ed wine storage temperatures.
Call service to have the tem-
perature sensor replaced.
Lower Zone
Temperature Sensor
Failed temperature sensor in the lower
zone compartment. Can lead to unwant-
ed wine storage temperatures.
Call service to have the tem-
perature sensor replaced.
Defrost Sensor
Failed defrost temperature sensor.
Causes unit to not defrost properly and
can create large frost build-up. Can lead
to water damage to the unit and sur-
rounding oor.
Unplug the power cord imme-
diately and call service to have
the defrost sensor replaced.
Temperature Sensor Error Codes
This alarm condition can be reset by closing the door or
momentarily pressing the "On/Off" keypad, (i.e.-if you
are cleaning the storage compartment, etc.). The alarm
will recur in 5-minutes if the alarm condition persists.
Alarms (Single and Dual Zone):
The control will alert you to conditions that could adversely
affect the performance of the appliance.
Door ajar - If the door is open, or not closed prop-
erly, for more than 5-minutes the System Status OK
indicator will turn-off, the "Door Ajar" indicator will ash,
and a tone will sound every 60 seconds. Additionally,
an "ALARM RESET" indicator will be displayed below
the "On/Off" keypad.
NOTE
The audible alarm can be muted, for each occurrence,
by pressing the lock keypad.