Owners Guide

9
!
CAUTION
Temperature Sensor Error Codes
Sensor Displayed Code Error Description Action to Take
Single Zone
Temperature
Sensor
Failed temperature sensor in the single
zone compartment. Can lead to
unwanted storage temperatures and/or
spoiled perishable goods.
Call service to have the
temperature sensor replaced and
remove all perishable goods from
compartment to prevent spoilage.
Defrost Sensor
Failed defrost temperature sensor.
Causes unit to not defrost properly and
can create large frost build-up. Can lead
to water damage to the unit and
VXUURXQGLQJÀRRU
Unplug the power cord
immediately and call service to have
the defrost sensor replaced.
The temperature sensors are monitored continuously. Any
OPEN or SHORTED circuit condition will initiate an
ERROR CODE as listed below:
Temperature Sensor Error Codes
Temperature mode:
The temperature mode is preset from the factory in Fahren-
KHLW)EXW\RXKDYHWKHRSWLRQWRFKDQJHLWWR&HQWLJUDGH
&7RFKDQJHWKHPRGHSUHVVDQGKROGWKHNH\SDG
while pressing the "+" keypad, then release the "-" keypad.
7KHWHPSHUDWXUHZLOOQRZEHGLVSOD\HGLQ&HQWLJUDGH&
Repeat the procedure to change the temperature mode
EDFNWR)DKUHQKHLW)
Adjusting the temperature:
To set or check the set-point temperature (with the control
RXWRIVOHHSPRGHSUHVVWKHRUNH\SDGV6(7ZLOO
be indicated on the user interface panel and the current
VHWSRLQWWHPSHUDWXUHZLOOGLVSOD\DQGÀDVK6XEVHTXHQW
presses of the "-" or "+" keypads will adjust the temperature
colder or warmer respectively. When you have reached
\RXUGHVLUHGVHWSRLQWWHPSHUDWXUHSUHVVWKH2Q2ႇNH\-
pad to accept, or do nothing and the "Set" mode will time-
out in 10-seconds accepting the displayed temperature as
the new set-point.
The available set-point temperature range for your appli-
DQFHLV)&WR)&,I\RXDWWHPSWWR
adjust the temperature outside of this range you will receive
DQDXGLEOHQRWL¿FDWLRQ
If you are using the appliance as a refrigerator for perish-
able foods, the set-point temperature should be set be-
WZHHQ)DQG)&DQG&
When initially loading your product with warm contents, it
may take up to 48-hours for the storage compartment tem-
perature to stabilize.
When making temperature set-point changes, it may take
up to 24-hours for the stored contents to stabilize at your
new set-point temperature.
)DFWRUVWKDWDႇHFWWKHVWRUDJHFRPSDUWPHQWVWDELOL]HG
temperature:
Changes to temperature setting.
Room temperature changes.
Temperature of stored contents.
- Loading warm contents.
- Cold content load will delay the change to a warmer
set-point temperature.
- Warm content load will delay the change to a colder
set-point temperature.
8VDJHQXPEHUDQGGXUDWLRQRIWKHGRRURSHQLQJV
Installation of the appliance in direct sunlight or next to
a heat source.
INSTALLING YOUR 7+(:$7(56833/<
9