MRS-600 INSTRUCTION MANUAL ACS-FB Series Price Computing Label Scale 1
CONTENT Safety First ................................................................................................................ 3 1.1 About warning and caution icons..................................................................... 3 1.2 Warning................................................................................................................ 3 1.3 Power plug and AC outlet ................................................................................. 4 1.4 Caution...................
Congratulations on your choice of an ACS-FB Series Price Computing Label Scale, designed to give you many years of service. 1 Safety First • • • To use this product safely and correctly, read this manual thoroughly and operate as instructed. After reading this guide, keep it close at hand for future reference. Always observe the warnings and cautions indicated on the product. 1.
. Never try to open the scale apart or modify it in any way. High-voltage components inside the scale create the danger of fire and electric shock. 1.3 Power plug and AC outlet 1. Use only a proper AC electronic outlet: 190V ~ 250V; Temperature: -10°C~ +40°C; Humidity: 40%~90%. Use beyond the indicated conditions creates the danger of malfunction, fire and electric shock. 2. Make sure the power plug is inserted as far as it will go. Loose plugs create the danger of electric shock, overheating and fire.
2 Summarize 2.1 External view Display Gradienter Tray Keyboar d Foot Printer Cover Printer 2.
2.
2.
2.6 Capability Parameter Maximum division of weighing-detection: MAX-MIN-e Precision LED Display Power supply Power consumption Operating temperature Humidity Printer feature Printer paper Print font Specification Singular division 3Kg—20g—1g 6Kg—40g—2g 5Kg—100g—5g 6/15Kg—40g—2/5g (scale with 15 Kg maximal weighing) 15/30Kg—80g—5/10g (scale with 30 Kg maximal weighing) 1/3000 F.
Release Lever U-Pin Printer Head Label Roll Shore Paper Chute Spool Shaft Note Load the label through the paper chute correctly and adjust the width of paper chute to the label. 1. 2. 3. 4. 5. 6. 7. 8. 2.8 Key features 10000 pieces of PLUs and PLUs data can be modified easily. PLU hot-keys can be edited and makes sales operation more quickly. Printing parameters and label code setting can be easily edited. Label code format designation is convenient.
3 Sales Operation 1. 2. 3. 4. 3.1 Inspection before usage Switch on the scale Make sure that the gradienter hole is clean Anything on the scale pan should be cleared up. Adjust the scale feet until the gradienter bubble showing adjustment to the horizontal. It is shown below: Correct Wrong 5. Make sure that printer paper sufficient and has been correctly installed. 3.2 Power up Procedure 1. Clean scale pan Key operation and display ON 2. Power switch “ON” 3. Zero indicator lighting up 0.000 0.
3.3 Weighing selling Procedure 1. Scale pan clear Key operation and display 2. Zero indicator lighting up 0.000 0.00 Zero Indicator 3. If Zero Indicator not lighting up, press “ZERO” key. [ZERO] 4. Tare Put the weighing pan on the scale pan, then press TARE key, then the “Tare” indicator will light up. 0.000 0.00 Tare indicator 5. Enter PLU Number To get product information, enter PLU number, and then press PLU key, then PLU indicator is lighting up. e.g. PLU number: 1 Unit price =USD 12.
3.4 Reset price selling Procedure 1. Scale pan clear Key operation and Display 2. Zero indicator lighting up 0.000 0.00 Zero Indicator 3. If Zero Indicator not lighting up, press “ZERO” key. 4. Tare Put the weighing pan on the scale pan, then press Tare key, then the “Tare” indicator will light up. [RE-ZERO] 0.000 5. Enter PLU Number To get product information, enter PLU number, and then press PLU key, then PLU indicator is lighting up. e.g. Tare indicator PLU number: 1 Unit price =USD 12.
3.5 Default weight and price selling Procedure 1. Scale pan clear Key operation and display 2. Zero indicator lighting up 0.000 0.00 Zero Indicator 3. If Zero Indicator not lighting up, press “ZERO” key. [ZERO] 4. Tare Put the weighing pan on the scale pan, then press TARE key, then the “Tare” indicator will light up. 0.000 0.00 Tare indicator 5. Enter PLU Number To get product information, enter PLU number, and then press PLU key, then PLU indicator is lighting up. e.g.
3.6 Sale In Package Procedure 1. To enter PLU code of packaged goods. “Package” indicator will light up. (Attn: This function can work only when “bagged selling" is set during programming.) Or use Hotkey: Pressing the PLU hotkey on keyboard to sale the goods directly. E.g. for COD1, press HOTKEY directly; for COD 89, press SHIFT+HOTKEY. Key operation and Display 1 100.00 100.00 Package indicator e.g. COD 1 PLU/COD e.g. COD PLU/COD 89 PLU/COD Procedure 1.
3.8. Date and time Procedure Under this interface. Key operation and Display 0.000 0.00 0.00 Press PACKET key Then you can see the date and time. It displays current day of 2007-07-06 (year-month-date), current time of 13-20-57 (hourminute-second) [PACKET] 2007 — 07 — 06 13—20—57 4. Technique Support Before you inform the technique representative, you may refer the error to the following list. Many questions occur do not because of the quality of the product rather a simple incorrect operation.