User's Manual
Table Of Contents
- About this Manual
- Product Description, Indications for Use, Contraindications, and Features
- Safety Information, Warnings, and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology (SET)
- rainbow Pulse CO-Oximetry Technology
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring (RAM) Technology
- Chapter 2: Radical-7 Descriptions
- Chapter 3: Setup
- Chapter 4: Operation
- Using the Touchscreen and Buttons
- Using Screenlock
- Using the Home Button
- Navigating the Radical-7
- About the Display View
- Accessing the Main Menu
- Navigating the Main Menu
- Parameter Settings
- Sounds
- Device Settings
- Trends
- About
- Chapter 5: Configurations
- Chapter 6: Alarms and Messages
- About Alarms
- Silencing the Alarms
- Adaptive Threshold Alarm (ATA) Feature
- 3D Alarms
- Messages
- Replace Sensor Message
- Replace Cable Message
- Replace Adhesive Sensor Message
- Incompatible Sensor Message
- Incompatible Adhesive Sensor Message
- No Adhesive Sensor Connected Message
- Interference Detected Message
- SpO2 Only Mode Message
- Low Battery Message
- Low Perfusion Index Message
- Low Signal IQ Message
- Low SpCO SIQ Message
- Low SpMet SIQ Message
- Low SpHb SIQ Message
- Speaker Failure Message
- No Cable Connected Message
- No Sensor Connected Message
- Pulse Search Message
- Sensor Initializing Message
- Sensor Off Patient Message
- Service Required Message
- Incompatible Cable Message
- Chapter 7: Troubleshooting
- Troubleshooting Measurements
- Signal Indication and Quality Indicator (SIQ)
- Dimly Lit Parameters
- Low Perfusion
- Low Signal Quality
- SpO2 Values Do Not Correlate With Clinical Assessment or Arterial Blood Gas Measurements
- Unexpected SpO2, SpCO, SpMet, or SpHb Reading
- Unexpectedly High SpCO Reading
- Difficulty Obtaining a Reading
- SpCO Reading Displays as Dashes
- Troubleshooting the Radical-7
- Troubleshooting Measurements
- Chapter 8: Specifications
- Performance
- Accuracy
- Resolution
- Electrical
- Environmental
- Physical Characteristics
- Trending
- Alarms
- Display Indicators
- Compliance
- Output Interface
- Wireless Radio (If Installed)
- Serial Interface Specifications
- Serial Interface Setup
- Analog Output and Nurse Call Specifications
- Symbols
- ISO Country Codes (FCC and EU)
- Citations
- Chapter 9: Service and Maintenance
- Appendix: Best Practices for Comparisons to Reference Measurements
- Index
Radical-7 Chapter 8: Specifications
www.masimo.com 117 Masimo
Compliance
EMC Compliance
EN55011: Radiated Emissions (CISPRR 11, 2009 Amendment A1:2010, Class B)
EN55011: Conducted Emissions (CISPRR 11, 2009 Amendment A1:2010, Class B)
EN301 489-17: Radiated Emissions (EN 301 489-01 V1.8.1:2008, Class B)
EN301 489-17: Conducted Emissions (EN 301 489-01 V1.8.1:2008, Class B)
EN61000-3-2: Limitations of quasi-stationary current Harmonic Emissions
(Requirements from EN 60601-1-2:2007)
EN301 489-17: Harmonic Emissions (EN 301 489-01 V1.8.1:2008)
EN61000-3-3: Limitations of voltage fluctuations and Flicker
EN301 489-17: Flicker (EN 301 489-01 V1.8.1:2008)
EN61000-4-2: ESD: Direct, Indirect, Vertical and Horizontal coupling plane
EN301 489-17: ESD: Direct, Indirect, Vertical and Horizontal coupling plane (EN
301 489-01 V1.8.1:2008)
EN61000-4-3: Radio Frequency Electromagnetic Field (80MHz to 2500MHz) at
3V/m, 2 Hz sine wave, 3 sec dwell
EN301 489-17: Radio Frequency Electromagnetic Field (80MHz to 2500MHz) at
3V/m (EN 301 489-01 V1.8.1:2008)
EN61000-4-4: Electric Fast Transient / Burst Immunity
EN301 489-17: Electrical Fast Transient / Burst Immunity
EN61000-4-5: Surge Immunity
EN301 489-17: Surge Immunity
EN61000-4-6: Conducted Immunity, Disturbances induced by RF Fields (150 KHz
to 80 MHz)
EN301 489-17: Conducted Immunity , Disturbances induced by RF Fields
EN61000-4-8: Power Frequency Magnetic Field Immunity
EN301 489-17: Voltage dips and interruptions
EN61000-4-11: AC voltage dips
EN61000-4-11: AC voltage interruptions
Equipment Classification
IEC 60601-1 / UL 60601-1
EN60601-1: 1990 + A!: 1993 +
A2: 1995
Type of Protection
Class 1 (on AC power), Internally powered
(on battery power)