User's Manual
Table Of Contents
- About this Manual
- Product Description, Indications for Use, Contraindications, and Features
- Safety Information, Warnings, and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology (SET)
- rainbow Pulse CO-Oximetry Technology
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring (RAM) Technology
- Chapter 2: Radical-7 Descriptions
- Chapter 3: Setup
- Chapter 4: Operation
- Using the Touchscreen and Buttons
- Using Screenlock
- Using the Home Button
- Navigating the Radical-7
- About the Display View
- Accessing the Main Menu
- Navigating the Main Menu
- Parameter Settings
- Sounds
- Device Settings
- Trends
- About
- Chapter 5: Configurations
- Chapter 6: Alarms and Messages
- About Alarms
- Silencing the Alarms
- Adaptive Threshold Alarm (ATA) Feature
- 3D Alarms
- Messages
- Replace Sensor Message
- Replace Cable Message
- Replace Adhesive Sensor Message
- Incompatible Sensor Message
- Incompatible Adhesive Sensor Message
- No Adhesive Sensor Connected Message
- Interference Detected Message
- SpO2 Only Mode Message
- Low Battery Message
- Low Perfusion Index Message
- Low Signal IQ Message
- Low SpCO SIQ Message
- Low SpMet SIQ Message
- Low SpHb SIQ Message
- Speaker Failure Message
- No Cable Connected Message
- No Sensor Connected Message
- Pulse Search Message
- Sensor Initializing Message
- Sensor Off Patient Message
- Service Required Message
- Incompatible Cable Message
- Chapter 7: Troubleshooting
- Troubleshooting Measurements
- Signal Indication and Quality Indicator (SIQ)
- Dimly Lit Parameters
- Low Perfusion
- Low Signal Quality
- SpO2 Values Do Not Correlate With Clinical Assessment or Arterial Blood Gas Measurements
- Unexpected SpO2, SpCO, SpMet, or SpHb Reading
- Unexpectedly High SpCO Reading
- Difficulty Obtaining a Reading
- SpCO Reading Displays as Dashes
- Troubleshooting the Radical-7
- Troubleshooting Measurements
- Chapter 8: Specifications
- Performance
- Accuracy
- Resolution
- Electrical
- Environmental
- Physical Characteristics
- Trending
- Alarms
- Display Indicators
- Compliance
- Output Interface
- Wireless Radio (If Installed)
- Serial Interface Specifications
- Serial Interface Setup
- Analog Output and Nurse Call Specifications
- Symbols
- ISO Country Codes (FCC and EU)
- Citations
- Chapter 9: Service and Maintenance
- Appendix: Best Practices for Comparisons to Reference Measurements
- Index
Radical-7 Chapter 9: Service and Maintenance
www.masimo.com 128 Masimo
indicator continuously flashes. When the temperature returns to
recommended operating conditions, proper battery charging proceeds.
The Handheld battery requires approximately 4 hours for charging. The
Docking Station battery requires approximately 6 hours for charging.
When both the Handheld Battery Charging indicator and the Docking
Station Battery Charging indicator turn off, additional trickle charging may
occur to complete charging.
Memory effects of the battery may shorten run-time. When battery run time
is significantly reduced, it is advisable to completely discharge and fully
recharge the battery. Charging can occur while the Handheld is docked and
turned on, the most efficient charge times are achieved when the Handheld
is turned off.
During battery operation of the Radical-7, note that the following operating conditions affect
the estimated run time of the included rechargeable batteries:
Estimated Run Times of Battery Power
The following tables outline the estimated run times of the battery-powered Radical-7. The
time estimates are based on a Radical-7 with fully charged batteries. The time estimates are
also based on a Radical-7 with and without the back-light illuminated.
The Radical-7 is always configured to include the Handheld battery. It may optionally be
configured to include the Docking Station battery. Determine the configuration of your
system before referencing the following tables.
Run Time for Handheld Only
In this configuration, the Radical-7 is configured to only include the Handheld battery
(standard configuration). When running on battery power, it is advisable to operate only the
Handheld. On battery power, it is possible to operate the Standalone (Handheld attached to
the Docking Station with the Handheld battery providing power to the Docking Station).
However, the capacity of the Handheld battery pack is not sufficient to support this mode for
long periods of time.
For optimal battery run time, configure the device to automatically adjust the brightness.
See Brightness on page 77.
Configuration
Operation Mode
Minimum run
time
Handheld only
Handheld, undocked, not connected to AC power
4 hours
Handheld only
Handheld docked, not connected to AC power
1 hour