1.6.4 REPLACING THE SIDE ACCESS PANEL
1. Fit the holes in the top flange of the panel over the top locating pins.
2. Pushing upward, swing the bottom of the panel in until the screw holes align.
3. Replace the two screws. Do not overtighten.
1.6.5 REMOVING THE PIEZO/FAN SWITCH ACCESS PANEL (Not ECS II )
1. Remove the screws securing the panel to the top rear of the cabinet.
2. Lift the panel clear.
1.6.6 REPLACING THE PIEZO/FAN SWITCH ACCESS PANEL (Not ECS II )
1. Offer the panel into position and re-fit the screws. Do not overtighten.
1.7 REMOVING AND REPLACING THE BURNER
1. Disconnect the gas and power supplies.
2. Remove any dress guard, the louvre assembly and glass . See Section 1.1.
3. Lift all the logs out carefully, remembering they are easily damaged. Before lifting each log, check
that there are no wire ‘skewers’ fixing it to other logs. If there are skewers, withdraw them
carefully, remembering where they are for replacement when re-assembling. The skewers are mainly
for holding the logs during transit. It is normal for some to burn away during use.
4. Remove the embers from the burner top and store them in a plastic bag.
5. Inside the firebox, remove the air hood above the right rear of the burner (2 screws).
6. Remove the two front burner retaining screws, and lift out the burner by raising the end opposite
the injector (the left hand end) first, and moving the burner about 10mm to the left to disengage it
from the injector. Take care not to damage the igniter assembly.
7. Follow the above steps in reverse to replace the burner. When re-installing the embers, place them
no further back than 50mm from the front of the burner, and do not block the ventilation slots.
NOTE: FOR QUICK IGNITION, IT IS IMPORTANT THAT THE SPARK GAP AND THE
GAP BETWEEN THE EARTH TERMINAL AND THE FLAME SENSOR TERMINAL
ARE DIRECTLY OVER THE GAS EMISSION HOLES IN THE BURNER. IF THEY ARE
NOT, ADJUST THE BRACKET WHICH SUPPORTS THE TERMINAL ASSEMBLY
ACCORDINGLY.
LOG IDENTIFICATION
Rear Log: Mounting centres 340mm
Left Centre Log: Mtg. crs. 115mm
Left Front Log: Mtg. crs 93mm
Right Lower Log: Mtg.crs 122mm
Right Upper Log length: 245mm
Centre Log length: 255mm
FITTING THE LOGS
Fit the first four logs on their mounting posts
in the following order:-
1. The Rear Log
2. The Left Centre Log
3. The Left Front Log.
4. The Right Lower Log
Then place the Right Upper Log on top of the
hollow in the right lower log maintaining the
dimensions as shown.
Place the Top Log with its butt end sitting
against the raised front lip of the burner. Verify
the correct distances to the end of the air
hood.
Spread the embers as detailed above.
Re-fit the glass as described in 1.2.1.