Service manual

G.Fire Service Manual 17 Issue A — © Masport, March 2004
2. Confirm correct engagement by pulling forward gently on the top of the louvre assembly.
3. To fit a bottom louvre assembly, fit it as for a top assembly, but make sure the retainins screw at the
bottom engages with its clip and then push in on the head of the screw until it ‘clicks’.
2.3.2 DRESS GUARDS (IF REQUIRED)
Madrid:
1. The guard is retained simply by clipping its retaining lugs between the glass and the steel frame at
each side of the curved glass.
Piccolo and Sofia:
1. The louvre assemblies must be removed for fitting and removing the dress guard.
2. Angling the guard forward at the top, fit the two lugs at the top of the guard over the lugs at each
end of the top glass trim.
3. Swing the lower edge of the guard inwards to engage the bottom lugs under the firebox base..
4. Replace the louvre assemblies.
2.4 REMOVING AND REPLACING THE BURNER
1. Turn off the gas and disconnect any power supply.
2. Remove any dress guard, the louvre assemblies and the glass . See above.
3. Lift all the logs out carefully, remembering they are easily damaged. Before lifting each log, check
that there are no wire ‘skewers’ fixing it to other logs. If there are skewers, withdraw them
carefully, remembering where they are for replacement when re-assembling. The skewers are mainly
for holding the logs during transit. It is normal for some to burn away during use.
4. Remove the embers from the burner top and store them in a plastic bag.
5. Inside the firebox, remove the air hood above the right rear of the burner (2 screws).
6. Remove the two front burner retaining screws, and lift out the burner by raising the end opposite
the injector (the left hand end) first, and moving the burner about 10mm to the left to disengage it
from the injector. Take care not to damage the igniter assembly.
7. Follow the above steps in reverse to replace the burner.
NOTE: FOR QUICK IGNITION IT IS IMPORTANT THAT THE SPARK GAP AND THE GAP BETWEEN THE
EARTH TERMINAL AND THE FLAME SENSOR TERMINAL ARE DIRECTLY OVER THE GAS
EMISSION HOLES IN THE BURNER. IF THEY ARE NOT, ADJUST THE BRACKET WHICH
SUPPORTS THE TERMINAL ASSEMBLY ACCORDINGLY.
LOG IDENTIFICATION
Rear log mtg. centres - 340 mm
Left Centre log mtg. centres - 115 mm
Left Front log mtg centres - 93 mm
Right Lower log mtg. centres - 122 mm
Right Upper log length - 245 mm
Centre log length - 255 mm
Fit the first four logs on their mounting posts
in the following order:-
1. The Rear log
2. The Left Centre log
3. The Left Front log
4. The Right Lower log
Place the right Upper log on top of the hollow
in the right Lower log as illustrated,
maintaining the 130 dimension shown.
Place the Top log, positioned as shown with its
butt end sitting against the raised front lip of
the burner. Verify the correct distances to the
right side of the firebox.
5. Spread embers between and under the logs
to 50 mm back from front lip of burner, and
also on the floor of the firebox at each side of
the burner. Do not block the ventilation slots
in the burner.