Manual
27
CV - Table
Standard settings (D = Factory Default, A = analog operation)
Table of conguration variables (CV table)
CV Description D A Range Note
1 Loco address 3 1...127 if CV 29 bit 5 = 0
7 Software version --- --- read only
8 Manufacturer ID 123 --- read only
8 Decoder reset functions (see attachment 1)
(3 reset ranges available)
11
16
22
basic settings
Programming lock
FA1
11 DCC Timeout 2 √ 0...100
100ms per value
0 = analog operation off
15 Programming lock 165 0...255
Key
16 Programming lock 165 0...255 Lock
17 Long loco address (High Byte)
1000
128...
10239
if CV 29 bit 5 = 1
18 Long loco address (Low Byte)
29 NMRA Conguration 4 √ bitweise programming
Bit Value OFF (Value 0) ON (add all active values)
Bit 2 4 digital operation only digital + analog operation
Bit 5 32 short address (CV 1) long address (CV 17/18)
110 FA1: Command allocation A 1 1...68
255 Decoder type 165 --- read only
Attachment 1 – CV-Values at decoder reset
Resetwert 11 16 22
CV 1 11 17 18 29 15 16 110
Wert 3 2 195 232 4 165 165 1