INSTALLATION & OPERATIONS MANUAL MASTER-BILT Products 908 Highway 15 North New Albany, MS 38652 Phone: 800-6848988 REV 2-29-12 By: LN
TABLE OF CONTENTS I. PACKAGING……………………………………………………………………….………………..3 II. INSTALATION………………………………………………………….…………………………..3 III. OPERATIONS……………………………………………………….…………………….………3-5 1. Electrical………………………………………………………………...………………….…...3 2. Temperature Control…………………………………………..………………………………...4 3. Loading Ice……………………………………………………………….……………….…….5 IV. MAINTENANCE……………………………………………………………………….……………5 1. Refrigeration…………………………………………………………….………………………5 2. Defrosting……………………………………………………………………….………………5 A. Cold Wall (CW) B.
Remove plastic overwrap, banding and corrugation packaging. The wooden skid is removed by unscrewing 6-8 hex head screws holding the skid. Glass Door Models: Remove glass door support bracket(s) and protective foam block(s). All merchandisers are tested, inspected and carefully packaged to ensure each unit arrives ready for operation. Please return postage paid warranty card to activate merchandiser warranty. (See back page of manual) Retain for future reference.
The merchandiser must be plugged into a 115 volt, 60 HZ grounded receptacle electrical outlet with a circuit fuse or breaker. (See figure 1). The condensing unit data plate will indicate the maximum fuse/breaker size. DO NOT use extension cords. Extension cords may decrease the voltage to the unit and ultimately cause the compressor to fail. NOTE: Some outdoor locations require ground fault interrupt (GFI) outlets. These outlets may trip upon condensing unit start.
3. Loading Ice: After merchandiser is operating at required temperature, load with packaged ice. Stacked packaged ice should not exceed heights that will cause poor refrigeration efficiency. Approximately 6" needs to be clear from top of stacked ice to top of inside interior for effective refrigerated ice storage. AutoDefrost units require good fan air flow for effective circulation.
3. Electrical: Inspect each month all power harnesses for any cracks, abrasions or damage to connection plugs. Replace any defective wiring or harnesses. 4. Door(s): Inspect each month for component wear, function and secure attachment. A. Gasket(s) should be examined for tears or any other problems that would cause loss of seal. Replace torn/worn gaskets to maintain correct temperature and refrigeration efficiency. B.
5. Cleaning: Schedule yearly cleaning of merchandiser interior with solution of 8 tablespoons of baking soda to 1 gallon of warm water. DO NOT use strong detergents, abrasive cleansers, solvents, wax or polish as they are likely to leave objectionable odors which may be absorbed by the ice. Wash the outside surfaces with a mild soap and warm water applied with a soft sponge or cloth. Wax exterior to maintain appearance and extend life of paint.
ITEM DESCRIPTION PART # 1. Condensing Unit: Provide condensing unit model number 2. Drier Timer Thermostat Power Harness (AD & CW) Coldwall Adapter Harness 1323002 1328023 1328046 1270047 1270043 Unit Cooler Evaporator Parts: Fan Guard Fan Blade Fan Mounting Bracket Fan Motor Defrost Limit Thermostat LCL 120 Defrost Heater LCL 170 Defrost Heater LCL 190/280 Defrost Heater 1396023 1392008 1101401 1393029 1328003 1261007 1261008 1261009 3. 4. ITEM 14.
¬(WY ¬ ¬.ORTH¬s¬.EW¬!LBANY ¬-3¬ ¬s¬ ¬s¬&!8 ¬ 7ARRANTY¬0ARTS¬ ¬3ERVICE ¬ ¬s¬&!8 ¬ ,)-)4%$¬/.% 9%!2¬0!243¬ ¬,!"/2¬7!22!.49¬&/2¬4(%¬&/,,/7).'¬#!").