ICE MERCHANDISER Installation, Operation and Maintenance Instructions 1 1/08 N138647
INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading to insure all crates and cartons have been received. All units should be inspected for concealed damage by uncrating the units immediately. If any damage is found, it should be reported to the carrier at once, and a claim should be filed with the carrier.
The Ice Merchandiser utilizes a programmable controller to control the temperature and defrost settings. The controller, which is located on the facade of the unit, is factory set. Please see the default settings sheet and separate instructions that are included on the operation of this controller. After shutting the door on freezer models, a short amount of time must be allowed before the door can be reopened. This is due to the tight seal maintained between the door and the cabinet.
MAINTENANCE SERVICE AND ANALYSIS GUIDE MALFUNCTION POSSIBLE CAUSE SOLUTION Compressor will not start no hum 1. 2. 3. 4. 5. Service cord unplugged Fuse blown or removed Overload tripped Control stuck open Wiring incorrect 1. 2. 3. 4. 5. Plug in service cord Replace fuse Determine reasons and correct Repair or replace Check wiring against the diagram Compressor will not start hums but trips on overload protector 1. 2. 3. 4.