Owner`s manual

9
Match lighting the Rotisserie Burner (if applicable)
Repeat steps 1 through 4 of the “Lighting the Rotisserie Burner.
4. Insert a lit match or a butane lighter into the match lighting hole located next to the Rotisserie Burner electrode.
5. Push in and turn the Rotisserie Burner control knob counter clockwise to the “MAX” (Ignite) position. The Rotisserie Burner
should light.
Lighting the INFRARED Burner (if applicable)
1. Open the INFRARED Side Burner lid. Ensure all control knobs are in the “OFF” position
before opening the gas supply.
2. Turn on the gas supply valve at the tank (1 to 2 turns), or turn on the main gas supply valve.
3. Turn the INFRARED burner control knob to the “MAX” position.
Wait 5 seconds
4. Press and hold the ELECTRONIC IGNITER button.
5. If the INFRARED burner does NOT light, turn the knob to “OFF”. Turn o the LP or NG gas
supply and wait 5 minutes before repeating the lighting procedure.
6. If the INFRARED burner still does not light follow the match lighting procedure for the
INFRARED burner.
CAUTION:
If the infrared burner fails to light, immediately turn burner control knob “OFF” and wait 5 minutes before
re-lighting with a match.
Match lighting the INFRARED burner (if applicable)
1. Open the lid for the INFRARED side burner. Ensure all Control knobs are in the “OFF” position before opening the gas supply.
2. Turn on the gas supply valve at the tank (1 to 2 turns), or turn on the main gas supply valve.
3. Place a lit match or a butane lighter directly beside the INFRARED burner electrode.
4. Turn the INFRARED burner control knob to the “MAX” position. Be sure the burner lights and stays lit.
ATTENTION
Always preheat barbecue before starting to cook. Light all burners and adjust them to the “MAX” position
with the lid closed, until the desired temperature is reached. Following preheat, adjust the controls to low/
medium setting for most cooking requirements.
Turning Grill O
1. Turn all control knobs to the “OFF” position.
2. Turn LP cylinder o by turning hand-wheel clockwise to a full stop or turn o the natural gas supply valve.
WARNING
If the heat output is too low, the “Flow Limiting feature may have been activated by a gas leak or
improper lighting procedure. If so, turn “OFF” all control knobs and cylinder valve, and perform a “Leak
Test. If there are no leaks, perform a complete regulator “Flow Limiting Device reset.