Instructions / Assembly

Master Flow
®
EmberShield
®
Closeable Soffit Vent
Installation Instructions
(Figure 1)
Important: During installation, always wear appropriate safety glasses, gloves, hard hats, fall
restraints, and other safety equipment to avoid injury.
Step 1: Cut a 15” x 7.5” (391 mm x 191 mm) opening in the soffit or remove existing soffit vent. If
replacing an existing soffit vent, ensure the vent is no larger than 16” x 8” (406 mm x 203 mm).
Step 2: Center the EmberShield
®
Closeable Soffit Vent over the opening, making sure it is square
with the structure. Fasten in place through the holes in the vent with four included screws (Figure 1)
Step 3: If painting (not required), do not paint the screen or slider portion of the vent. After paint
dries, always ensure proper movement of the slider.
Step 4: During threat of wildfire, fully close the EmberShield
®
Vents to help prevent embers from
being drawn into attic. Otherwise, the vents must always remain open for proper attic ventilation.
If the EmberShield
®
Closeable Soffit Vents are located at hard-to-reach locations, it is recommended
that an extension pole (typically used for painting) be used to open and close the vents.
Note: It is recommended that you periodically open and close the vents to ensure they are
functioning properly.
Note: Always have a balanced attic ventilation system. In no case should the amount of exhaust
ventilation exceed the amount of intake ventilation. Always consult local building codes for other
ventilation requirements.